Height
- Maximum stockpile heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in commercial/industrial districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.40 ft
The maximum height of any stockpile shall be 25 feet in a residential district and 40 feet in a commercial or industrial district.
- Maximum stockpile heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in residential districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.25 ft
The maximum height of any stockpile shall be 25 feet in a residential district and 40 feet in a commercial or industrial district.
Other
- Access road setbackSetbackThe distance a building must be held back from a lot line. from property line20 ft
Any access road shall be a minimum of 20 feet from any property line except at the point of access to any public right-of-way.
- Distance from community character corridor150 ft
No stockpile shall be located within 150 feet of a community character corridor.
- Hours of operation
The construction activity shall be conducted between local sunrise and sunset and shall have no Sunday operations, unless for necessary maintenance of equipment essential for public health and safety.
- Maximum stockpile term2 years
Stockpiles shall be limited to a maximum term of two years.
- Stockpile setbackSetbackThe distance a building must be held back from a lot line. from off-site structure100 ft
Not less than 100 feet from any existing off-site structure.
- Stockpile setbackSetbackThe distance a building must be held back from a lot line. from property line50 ft
Not less than 50 feet from any property line in any zoning district.
- Stockpile side slope
Side slopes shall not exceed three feet in width to one foot in height (3H:1V).
From the ordinance
Setback areas for soil stockpiles shall be: Not less than 50 feet from any property line ... Not less than 100 feet from any existing off-site structure ... The maximum height of any stockpile shall be 25 feet in a residential district and 40 feet in a commercial or industrial district ... Stockpiles shall be limited to a maximum term of two years ... No stockpile shall be located within 150 feet of a community character corridor.