Falls Church, Virginia · General provision

Sec. 48-1101, Sec. 48-1102

Dimensional standards

lot requirementsSTREETbuildable areaFront 20 ftRear 20 ftSide 7.5 ftMIN LOT AREA6,000 sq ftMAX HEIGHT4 ft / 4 storiesMAX LOT COVERAGE60%
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Extracted standards

9 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Height

Other

Setback

From the ordinance

The building height, lot size and yard regulations indicated in this division shall be observed unless otherwise specified. ... Maximum building height shall be 4 stories or 45 feet, whichever is shorter. ... Maximum building lot coverage shall be 60%.
Sec. 48-1101, Sec. 48-1102