Falls Church, Virginia · District

MUR-2

Mixed-Use Redevelopment Option 2
Mixed useMixed Use RedevelopmentAll Falls Church districts0

Dimensional standards

MUR-2 lot requirementsSTREETbuildable areaFront 14 ftRear 14 ftSide 14 ftMIN LOT AREA2.5 acMAX HEIGHT87 ftMIN OPEN SPACE15%
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

3 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

Parking

  • Maximum surface parking percentage25 pct

    Surface parking shall not occupy more than 25 percent of the gross site area.

From the ordinance

The MUR option 2 may be utilized only where the MUR 2 symbol appears on the future land use plan map of the comprehensive plan within the B-2 zoning district. ... All MUR option 2 applications are subject to an 87-foot maximum height limitation.
Sec. 48-1081(b), Sec. 48-1080

Parking requirements

{
  "general": "Per division 2, with shared parking options"
}