Santa Paula, California · General provision

16.44.030

Dimensional standards

Extracted standards

13 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Fencing & walls

  • Hours of activation

    An electrified security fence shall only be energized during the hours when the general public does not have legal access to the protected property and shall be maintained by an automatic timer.

  • Liability insurance requirement

    The owner of the electrified security fence and the property owner(s), if different, are each required to carry general liability insurance in a minimum amount of $1,000,000 in the aggregate.

  • The height of a fence must not exceed ten feet or two feet higher than the existing perimeter fence, whichever is greater.

  • Minimum distance from hazardous materials storage25 ft

    Electrified security fences are prohibited within 25 feet of any outdoor area utilized for the storage, use, or handling of Hazardous Materials as defined in the 2019 California Fire Code.

  • Minimum distance from residential use when abutting6 ft

    When abutting a property zoned to allow a residential use, the electrified security fence must be located at least six feet from the residential use and must include a perimeter barrier consisting of a minimum six foot high solid wooden fence or block wall.

  • Minimum distance from street property line10 ft

    The electrified security fence must be located at least ten feet from any street property line or five feet from a separated sidewalk.

  • No electrified security fence shall be installed or operated unless it is completely surrounded by a non-electric perimeter barrier that is not less than six feet in height.

  • Installation and operational permits required

    The installation of an electrified security fence requires an approved installation permit. The operation of an electrified security fence requires a valid operational permit.

  • Electrified security fence permitted zones

    Electrified security fences are permitted only within the C-LI, LI, and I Zones and must comply with the standards and regulations contained in this division.

  • Power source requirements

    No electrified security fence shall be installed or operated with a power source other than a storage battery not exceeding 12 volts direct current, charged primarily with a solar panel; provided, however, in case of inclement weather or other conditions that inhibit the ability of the solar panel to fully recharge the battery, a charging device may be utilized for such purpose, if connected in a manner that ensures that the charging device cannot provide a source of power directly to the fence.

  • Electrified security fences are prohibited for use on property zoned exclusively residential.

Signage

  • Warning sign minimum size32 sqin

    The size of the warning signs shall be a minimum of four inches by eight inches and be viewable from both the interior and exterior of the protected property.

  • Warning sign spacing30 ft

    There shall be a minimum of one warning sign posted on the electrified security fence every 30 linear feet.

From the ordinance

Electrified security fences are permitted only within the C-LI, LI, and I Zones and must comply with the standards and regulations contained in this division. ... The height of a fence must not exceed ten feet or two feet higher than the existing perimeter fence, whichever is greater.
16.44.030