Dimensional standards
Lot
Height & bulk
Housing
- Two-family
- by_right
- Three-family
- by_right
- Four-plus family
- by_right
Uses
Permitted by right37
- Single-family, Attached
- Single-family, Detached
- Two-family Dwellings
- Townhouses
- Multifamily Dwelling
- Home Occupation
- Administrative Services
- Community Recreation
- Cultural Services
- Day Care Center
- Educational Facilities, College/University
- Educational Facilities, Primary/Secondary
- Home for Adults
- Life Care Facility
- Nursing Home
- Open Space
- Post Office
- Public Parks and Recreational Areas
- Public Recreation Assembly
- Religious Assembly
- Safety Services
- Utility Service, Minor
- General Office
- Medical Office
- Business Support Services
- Clinic
- Communication Services
- Funeral Home
- Laboratory
- Parking Facility
- Personal Services
- Restaurant, Fast Food
- Restaurant, General
- Restaurant, Small
- Studio, Fine Arts
- Veterinary Hospital/Clinic
- Accessory Structures
Conditional / special use7
Accessory1
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Density
- Maximum residential density27 bedrooms per acreacre43,560 square feet — about the size of an American football field without the end zones.
Maximum residential density: Twenty-seven (27) bedrooms per acre for acreage of the site devoted to residential use.
Height
- HeightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. increase with additional setbacksSetbackThe distance a building must be held back from a lot line.60 ft
Forty-five (45) feet; sixty (60) feet with additional one (1) foot per each foot of height, front, side and rear setbacks.
Other
- External speakers require conditional useConditional useAllowed only after a discretionary approval — usually a public hearing and a board vote. permit
Without external speakers only. Any use which incorporates an external speaker may be permitted only with a conditional use permit.
- Joint and cross access requirements
Adjacent commercial or office properties that generate 100 trips or more per day shall provide a cross access drive.
- Certain uses permitted by rightBy rightPermitted outright: if the plans meet the written rules, permission cannot be withheld. only in multi-establishment buildings
†Permitted by right only as part of a multi-establishment building; otherwise, by conditional use permit.
- Maximum percentage of site devoted to residential use30 pct
Maximum percentage of the site which may be devoted exclusively to residential use: Thirty (30) percent of total site.
- Minimum open spaceOpen spaceLand a development must leave unbuilt, sometimes required to be usable or planted. for residential portion30 pct
Minimum open space: Thirty (30) percent of the total site devoted to residential use.
- All utility lines underground
All utility lines, electric, telephone, cable television lines, etc., shall be placed under ground.
From the ordinance
Permitted uses: ... Site development: min lot 15,000 sq ft, frontage 30 ft, max coverage 60%, FAR 0.40, max height 45 ft.