17.114.100.G
Dimensional standards
Lot
Height & bulk
Servicing
- Applies near
- Specific Plan No. 342
- Geographic extent
- Planning Area 26 of Specific Plan No. 342, if a school is not constructed
Extracted standards
15 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Density
- Maximum units per building18 units
The maximum number of units within a building shall not exceed eighteen (18) feet.
Fencing & walls
- Minimum screen wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.6 ft
A minimum six foot high screen wall shall be located adjacent to any lower density zone.
Other
- Cornices and canopies encroachment
Cornices and canopies shall be allowed to encroach with no maximum requirement into setbacks.
- Eaves encroachment
Eaves shall be allowed to encroach with no maximum requirement into setbacks.
Garages opening to the front of lots shall be set back a minimum of eighteen (18) feet.
- Garage rear maximum setbackSetbackThe distance a building must be held back from a lot line.5 ft
Garages opening to the rear of lots shall not be set back greater than five feet, unless the setback exceeds eighteen (18) feet.
Garages opening to the rear of lots shall be set back a minimum of three feet from the existing street right-of-way, from any future street right-of-way, as shown on any specific plan of highways, or from the curb of an alley.
- Maximum architectural encroachment1 ft
Fireplaces, media niches, bay windows, porches, window boxes, and similar architectural features shall be allowed to encroach a maximum of one foot into setbacks on one side so that one side still maintains a minimum four foot setback.
- Maximum media niche width8 ft
Media niches shall be a maximum of eight feet in width.
- Maximum stairway/landing encroachment1 ft
Stairways and landings shall be allowed to encroach a maximum of one foot into setbacks.
- Minimum private open spaceOpen spaceLand a development must leave unbuilt, sometimes required to be usable or planted. (ground floor)80 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
The minimum private open space area for each lot, dwelling, or dwelling unit on the ground floor shall be eighty (80) square feet with minimum dimensions of eight feet by five feet.
- Minimum private open spaceOpen spaceLand a development must leave unbuilt, sometimes required to be usable or planted. (upper floors)40 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
The minimum private open space area for each lot, dwelling, or dwelling unit on second stories or greater shall be forty (40) square feet with minimum dimensions of seven feet by four feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. with encroachment4 ft
At least one side of the structure shall maintain a four foot setback regardless of encroachments.
- Second floor rear encroachment prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
No second floor structural encroachments shall be permitted within one foot of the rear property line.
Parking
- Tandem garages permitted
Tandem garages are permitted.
From the ordinance
Lot area shall be not less than two thousand (2,000) square feet with a minimum average width of thirty-five (35) feet and a minimum average depth of fifty-eight (58) feet.