Extracted requirements

Standards

A zoning ordinance states most of its rules in prose, not tables. Each one that could be read as a discrete requirement — a maximum sign area, a minimum fence setback, a riparian buffer width — is stored here with its value, its unit and the clause it was taken from.

10 standards in Wildfire

Defensible space annual maintenance

defensible_space_maintenance

Wildfire

Developments regulated by this chapter and within the state responsibility area (SRA) are required to provide annual maintenance of the defensible space area.

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Madera County Unincorporated

Defensible space required

defensible_space_required

Wildfire

Developments regulated by this chapter and within the state responsibility area (SRA)

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Madera County Unincorporated

Wildfire restriction

wildfire_restriction

Wildfire

The lot to be split shall not be located within a very high fire hazard severity zone, unless the site complies with all fire-hazard mitigation measures required by the MLFPD.

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Mammoth Lakes

Development prohibited in very high fire hazard zone

very_high_fire_hazard_zone_prohibited

Wildfire

No housing development shall be permitted on a vacant site located within a very high fire hazard severity zone, as indicated on maps adopted by the Department of Forestry and Fire Protection pursuant to Section 4202 of the Public Resources Code or as designated pursuant to subdivisions (a) and (b) of Section 51179.

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Marin County Unincorporated

Fire sprinkler required in Very High Fire Hazard Severity Zone

vhfhz_sprinkler_required

Wildfire

When located within the Very High Fire Hazard Severity Zone, a moveable tiny house shall be protected with an automatic fire sprinkler system

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Placer County Unincorporated

Ignition-resistant exterior walls required in VHFHSZ

ignition_resistant_walls_required

Wildfire

Exterior walls shall be constructed with ignition-resistant materials in compliance with Section R337

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Placer County Unincorporated

Glazed openings compliance in VHFHSZ

glazed_openings_compliance

Wildfire

Glazed openings, including skylights, shall comply with Section R337

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Placer County Unincorporated

Minimum front yard in State Responsibility Area

min_front_yard_sra_ft

30 ft
Wildfire

The minimum front yard requirement shall be not less than required in the applicable zone ... but in no case shall the minimum front yard requirement be less than thirty (30') feet from the center line of the street

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Plumas County Unincorporated

Minimum side and rear yard in State Responsibility Area

min_side_rear_yard_sra_ft

30 ft
Wildfire

The minimum side and rear yard requirements shall be at least thirty (30') feet from property lines

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Plumas County Unincorporated

Accessory building exception to 30-ft setback (fire resistant)

accessory_building_fire_resistant_exception

20 ft
Wildfire

A detached accessory building may be located within the thirty-foot setback when it is constructed using non-combustible or fire resistant materials ... and is located not closer than twenty (20') feet to another building.

Districts affected

A general provision — the clause names no specific district, so it applies jurisdiction-wide. See every district in Plumas County Unincorporated