Tappahannock
Zoning districts
8 districts, grouped by category.
Industrial
1Residential
5Manufactured Home Park District
- Min lot
- 435,600 sq ft (10 ac)
- Permitted uses
- 3
- Max height
- 75 ft
- Max density
- 35 du/ac
- Permitted uses
- 4
- Max height
- 45 ft
- Max density
- 35 du/ac
- Permitted uses
- 6
- Max height
- 40 ft
- Max density
- 35 du/ac
- Permitted uses
- 8
- Front setback
- 50 ft
- Permitted uses
- 8
General provisions
159 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.
The Town incorporates by reference the driveway specifications of the Virginia Department of Transportation.
The Town specifications for vehicle accommodation area surfaces in the Town Road Ordinance shall be as follows, at a minimum: 1. Compacted sub-base with minimum CBR-20 (no topsoil). 2. A minimum of six-inch aggregate base material Type 1 or Type 2. 3. Hot mix Type SM-2 at 165 pounds per square yard. 4. All materials to be placed in accordance with the Virginia Department of Transportation Road and Bridge Specifications, January 1991.
Bufferyard requirements are stated in terms of the width of the bufferyard and the number of plant units required per 100 linear feet.
The compatible relationship of architecture along U.S. 17 is of public concern.
Proposed site lighting, other than streetlights, should comply with the following guidelines: Site lighting shall be of low intensity from a concealed source...
These provisions shall apply to all privately and publicly owned lands within the jurisdiction of the Town of Tappahannock and identified as areas of special flood hazard identified by the community or shown on the flood insurance rate map (FIRM) or included in the flood insurance study (FIS) that are provided to the Town of Tappahannock by FEMA.
A sign up to three feet in area... (and other sign definitions)
A home occupation... provided that: ... one permitted sign not to exceed four square feet... no more than one person not a member of the family... not occupy more than 25 percent of the floor area.
Use of these vehicles as permanent dwelling units is expressly prohibited by this Ordinance.
Within any floodway area, no encroachments, including fill, new construction, substantial improvements, or other development shall be permitted unless it has been demonstrated through hydrologic and hydraulic analysis... The placement of manufactured homes (mobile homes) is prohibited, except in an existing manufactured home (mobile home) park or subdivision.
Until a regulatory floodway is designated, no new construction, substantial improvements, or other development (including fill) shall be permitted within the areas of special flood hazard, designated as Zones A1-30, AE, or AH on the FIRM, unless it is demonstrated that the cumulative effect of the proposed development... will not increase the water surface elevation of the base flood more than one foot.
Until a regulatory floodway is designated, no new construction, substantial improvements, or other development (including fill) shall be permitted within the areas of special flood hazard, designated as Zones A1-30, AE, or AH on the FIRM, unless it is demonstrated that the cumulative effect of the proposed development will not increase the water surface elevation of the base flood more than one foot.
When such base flood elevation data is utilized, the lowest floor shall be elevated to or above the base flood level plus 18 inches.
When such base flood elevation data is utilized, the lowest floor shall be elevated to or above the base flood level plus 18 inches.
All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated to or above the flood depth specified on the FIRM... If no flood depth number is specified, the lowest floor... shall be elevated no less than two feet above the highest adjacent grade.
All new construction and substantial improvements of residential structures shall have the lowest floor, including basement, elevated to or above the flood depth specified on the FIRM, above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM. If no flood depth number is specified, the lowest floor shall be elevated no less than two feet above the highest adjacent grade.
Buildings and structures within this zone shall have the lowest floor elevated to or above the base flood elevation plus one foot of freeboard, and must comply with the provisions in Article III, Section 3.1.A.2 and Article IV, Sections 4.2 and 4.3.
Buildings and structures within this zone shall have the lowest floor elevated to or above the base flood elevation plus one foot of freeboard, and must comply with the provisions in Article III, Section 3.1.A.2 and Article IV, Sections 4.2 and 4.3.
All new construction and substantial improvements in Zones V and VE, including manufactured homes, shall be elevated on pilings or columns so that: (1) The bottom of the lowest horizontal structural member of the lowest floor... is elevated to or above the base flood level plus 18 inches... or elevated at least two feet above the base flood level if the lowest horizontal structural member is perpendicular to the direction of wave approach; ...
All new construction and substantial improvements in Zones V and VE, including manufactured homes, shall be elevated on pilings or columns so that the bottom of the lowest horizontal structural member of the lowest floor is elevated to or above the base flood level plus 18 inches, if the lowest horizontal structural member is parallel to the direction of wave approach or elevated at least two feet above the base flood level if perpendicular.
Source documents
The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.
- Chapter 16.9K charsRead →
- Chapter 1012.6K charsRead →
- Chapter 11173.8K charsRead →
- Chapter 1256.1K charsRead →
- Chapter 13113.4K charsRead →
- Chapter 1440K charsRead →
- Chapter 1530.5K charsRead →
- Chapter 1619.2K charsRead →
- Chapter 1712.2K charsRead →
- Chapter 1862K charsRead →
- Chapter 1976.5K charsRead →
- Chapter 24.7K charsRead →
- Chapter 2021.6K charsRead →
- Chapter 2114.4K charsRead →
- Chapter 2254.8K charsRead →
- Chapter 2333.2K charsRead →
- Chapter 243.2K charsRead →
- Chapter 253.9K charsRead →
- Chapter 2612.7K charsRead →
- Chapter 2721.2K charsRead →
- Chapter 2811.8K charsRead →
- Chapter 29145K charsRead →
- Chapter 329.5K charsRead →
- Chapter 30104K charsRead →
- Chapter 314.3K charsRead →
- Chapter 4157.2K charsRead →
- Chapter 529.7K charsRead →
- Chapter 679.8K charsRead →
- Chapter 721.8K charsRead →
- Chapter 811.8K charsRead →
- Chapter 915.2K charsRead →