Extracted standards
4 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Aggregate base material thickness6 in
A minimum of six-inch aggregate base material Type 1 or Type 2.
- Construction specification reference
All materials to be placed in accordance with the Virginia Department of Transportation Road and Bridge Specifications, January 1991.
- Hot mix type and weight165 lb/sq yd
Hot mix Type SM-2 at 165 pounds per square yard.
- Compacted sub-base minimum CBR20 CBR
Compacted sub-base with minimum CBR-20 (no topsoil).
From the ordinance
The Town specifications for vehicle accommodation area surfaces in the Town Road Ordinance shall be as follows, at a minimum: 1. Compacted sub-base with minimum CBR-20 (no topsoil). 2. A minimum of six-inch aggregate base material Type 1 or Type 2. 3. Hot mix Type SM-2 at 165 pounds per square yard. 4. All materials to be placed in accordance with the Virginia Department of Transportation Road and Bridge Specifications, January 1991.