County (unincorporated) · Virginia

Henrico County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
25
Districts
507
Extracted rules
1,681
Standards
8
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

25 districts, grouped by category.

Residential

14
R-0Residential

R-0 One-Family Residence District

Henrico County Unincorporated, VA
Min lot
43,560 sq ft (1 ac)
Max height
40 ft
Permitted uses
4
R-0AResidential

R-0A One-Family Residence District

Henrico County Unincorporated, VA
Min lot
35,000 sq ft (0.8 ac)
Max height
40 ft
Permitted uses
4
R-1Residential

R-1 One-Family Residence District

Henrico County Unincorporated, VA
Min lot
25,000 sq ft (0.57 ac)
Max height
40 ft
Permitted uses
4
R-1AResidential

R-1A One-Family Residence District

Henrico County Unincorporated, VA
Min lot
21,500 sq ft (0.49 ac)
Max height
40 ft
Permitted uses
4
R-2Residential

R-2 One-Family Residence District

Henrico County Unincorporated, VA
Min lot
18,000 sq ft (0.41 ac)
Max height
40 ft
Permitted uses
4
R-2AResidential

R-2A One-Family Residence District

Henrico County Unincorporated, VA
Min lot
13,500 sq ft (0.31 ac)
Max height
40 ft
Permitted uses
4
R-3Residential

R-3 One-Family Residence District

Henrico County Unincorporated, VA
Min lot
11,000 sq ft (0.25 ac)
Max height
40 ft
Permitted uses
4
R-3AResidential

R-3A One-Family Residence District

Henrico County Unincorporated, VA
Min lot
9,500 sq ft
Max height
40 ft
Permitted uses
4
R-4Residential

R-4 One-Family Residence District

Henrico County Unincorporated, VA
Min lot
8,000 sq ft
Max height
40 ft
Permitted uses
4
R-4AResidential

R-4A One-Family Residence District

Henrico County Unincorporated, VA
Min lot
7,750 sq ft
Max height
40 ft
Permitted uses
4
R-5Residential

R-5 General Residence District

Henrico County Unincorporated, VA
Min lot
1,260 sq ft
Max height
200 ft
Front setback
35 ft
Max density
12 du/ac
Permitted uses
5
R-5AResidential

General Residence District

Henrico County Unincorporated, VA
Min lot
5,625 sq ft
Max height
40 ft
Front setback
15 ft
Max density
6 du/ac
Permitted uses
7
R-5BResidential

R-5B General Residence District

Henrico County Unincorporated, VA
Min lot
3,000 sq ft
Max height
40 ft
Max density
10 du/ac
Permitted uses
4
R-6Residential

R-6 General Residence District

Henrico County Unincorporated, VA
Min lot
1,260 sq ft
Max height
200 ft
Front setback
35 ft
Max density
12 du/ac
Permitted uses
8

General provisions

482 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Sec. 24-44378 standards

Tower-mounted wind energy systems must not be located within a front yard.

Sec. 24-44375 standards

Tower-mounted wind energy systems must not be located within a front yard. The wind energy system must be set back from all property lines and overhead utility lines a distance equal to its total extended height plus 15 feet. ... must not exceed the maximum height allowed in the zoning district plus 60 feet. ... Sound produced by the wind energy system under normal operating conditions, as measured at the property line, must not exceed 55 dBA at any time. ... Wind turbine blade tips and vanes must have a minimum ground clearance of 15 feet

Sec. 24-44382 standards

A data center is allowed as an accessory use to an office or industrial use, subject to the following standards in addition to the standards of Sec. 24-4328.B:

Sec. 24-44381 standards

All equipment necessary for operating the data center must be contained within an enclosed building or screened by opaque walls to minimize transmission of sound.

Sec. 24-450310 standards

Unless otherwise specified in this Ordinance, all temporary uses and structures must:

Sec. 24-45053 standards

The temporary building, structure, or use must not be moved onto the project site prior to the issuance of a temporary use permit and any required building permit for the related project and must be removed within 30 days after either (i) the expiration of the building permit, or (ii) the issuance of the final certificate of occupancy for the building or completed development, at which time the temporary use permit will expire.

Sec. 24-45052 standards

The Planning Director will issue the temporary use permit for an appropriate period of time not to exceed 36 months and may extend the temporary use permit for an additional period not to exceed 36 months on finding that the building construction or land development is proceeding in a timely manner.

Sec. 24-45065 standards

A temporary family healthcare home must:

Sec. 24-45062 standards

A temporary use permit for a family healthcare home will be valid for one year. ... Be connected to all water, sewer, and electric utilities serving the primary residence

Sec. 24-45074 standards

The farmers' market must not operate for more than 50 days in any calendar year.

Sec. 24-45072 standards

The farmers' market must not operate for more than 50 days in any calendar year. The farmers' market must operate only during daylight hours.

Sec. 24-45084 standards

A temporary flea market must not operate for more than 30 days in any calendar year.

Sec. 24-45082 standards

A temporary flea market must not operate for more than 30 days in any calendar year. ... Stalls, sales tables, and any other facilities related to the flea market must be located at least 25 feet from any adjoining street.

Sec. 24-45093 standards

A mobile food unit must be operated on level ground that is surfaced with pavement, gravel, or a similar dustless, all-weather material to ensure safe and convenient pedestrian access.

Sec. 24-45092 standards

A mobile food unit must be operated on level ground that is surfaced with pavement, gravel, or a similar dustless, all-weather material to ensure safe and convenient pedestrian access. ... must not be operated within a required parking space or be parked in a driveway, drive aisle, sidewalk or other pedestrian way, fire lane, or required landscaped area.

Sec. 24-45103 standards

A single model sales home or unit may be located on a new development site and temporarily used for sales or leasing uses associated with the development, subject to the following standards:

Sec. 24-45102 standards

There must be no more than one model sales home or unit per builder in the development, and no more than three model homes per development. At least one parking space must be provided for every 300 square feet of gross floor area devoted to the model sales home.

Sec. 24-45117 standards

In Residential districts, storage containers, other than those located on construction sites, must not exceed 130 square feet in floor area or eight feet in height.

Sec. 24-45116 standards

In Residential districts, storage containers, other than those located on construction sites, must not exceed 130 square feet in floor area or eight feet in height. In districts other than Residential districts and on construction sites in Residential districts, storage containers must not exceed 160 square feet in floor area or eight and one-half feet in height. ... One period not exceeding 10 consecutive days in any six-month period in Residential districts; or One period not exceeding 30 consecutive days in any six-month period in districts other than Residential districts

Sec. 24-45123 standards

A temporary recyclables collection point must not be operated for more than one period not exceeding 30 consecutive days in any six-month period.

Source documents

The chapters of the adopted code that were retrieved, read and extracted from. Everything above traces back to one of these.