Sanger, California · District

C-5

Highway Commercial District
CommercialHighwayAll Sanger districts0

Dimensional standards

C-5 lot requirementsSTREETSTREETbuildable areaFront 30 ftRear 0 ftSide 0 ftStreet side 20 ftMAX HEIGHT35 ft / 2 stories
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

12 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Design

  • Design guidelines

    All development shall comply with provisions of the Sanger Design Guidelines and the design guidelines contained within the North Academy Corridor Master Plan.

Other

  • Access requirements

    The provisions of the C-1 district, subsection 90-575(5), shall apply.

  • Director's review permit required

    subject to first securing a director's review permit

  • Loading space requirements

    The provisions of section 90-892 shall apply.

  • Mural permit required

    Murals subject to the approval of a mural permit pursuant to section 90-891(9).

  • Offices limited to component of permitted use

    Offices as a component of a permitted use.

  • where the rear of the C-5 district abuts a residential district, there shall be a rear yard of not less than 20 feet, of which five feet shall be landscaped and maintained

  • where the C-5 district abuts a residential district there shall be a side yard on the C-5 lot on the side abutting the residential district of not less than ten feet

  • Site plan review

    Before any building or structure is erected, or any existing building or structure is enlarged, on any lot in this district, a site plan review shall have been approved.

  • Wall requirements along residential boundaries

    None required other than along the boundaries between the C-5 district and abutting residential districts, in which case the requirements set forth in the C-1 district, subsection 90-575(3), shall apply.

Parking

Signage

  • Sign regulations

    The provisions of section 90-891 (Signs) shall apply.

From the ordinance

The C-5 district is intended to establish appropriate areas along Highway 180 for the development of commercial uses... building height not greater than two stories, not to exceed 35 feet; front yard not less than 30 feet; parking 6 spaces per 1,000 sq ft.
Sec. 90-1122 through 90-1128

Parking requirements

{
  "commercial": "6 spaces per 1,000 sq ft of floor area"
}