Port Hueneme, California · District

R-1

Single-Family Zone
ResidentialSingle FamilyAll Port Hueneme districts0

Dimensional standards

R-1 lot requirementsSTREETbuildable areaFront 20 ftRear 15 ftSide 5 ftMin width 60 ftMin depth 100 ftMIN LOT AREA6,000 sq ftMAX HEIGHT30 ftMAX LOT COVERAGE35%MAX FAR0.5MAX DENSITY1 du/acMIN UNIT SIZE800 sq ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Extracted standards

8 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Addition matching requirement

    Building additions, garages and carports as permitted and required, shall be constructed so as to match the exterior composition of the principal dwelling

  • Minimum eave overhang16 in

    All main buildings and structures shall have eave overhang of a minimum of sixteen (16) inches or a minimum of one (1) foot high parapet

  • Metal siding restriction

    No metal siding shall be permitted in front yards or unscreened side yards with the exception of non-corrugated, horizontally applied metal-lapped siding.

  • Minimum exterior width20 ft

    No dwelling unit ... shall have an exterior width of less than twenty (20) feet

  • Roof material

    No sheet metal roofs shall be permitted except those which are covered by wood shake, wood shingle, asphalt shingle, fiberglass shingle, concrete or clay tiles, or built-up roofs

  • A minimum of seventy-five (75) percent of the length of the exterior wall of the second story on a new dwelling or an addition to an existing dwelling shall be set back a minimum of two (2) times the required side yard setback and one-half (½) times the required front yard setback

  • Second story window glazing

    Openings on a second story exterior wall located on a side yard setback shall use translucent glazing or celestial windows

Parking

  • Garage requirement for large homes

    a three-car enclosed garage is constructed on the lot when the total number of bedrooms within the dwelling exceeds four (4) and/or when the total number of bathrooms ... exceed three (3)

From the ordinance

No building hereafter erected or structurally altered shall exceed a height of thirty (30) feet. ... a front yard of not less than twenty (20) percent of the depth of the lot, provided such front yard need not exceed twenty (20) feet. ... a side yard on each side of the building of not less than ten (10) percent of the width of the lot, provided, that such side yards need not exceed five (5) feet in width. ... a rear yard of not less than fifteen (15) percent of the depth of the lot, provided such rear yard need not exceed fifteen (15) feet. ... a lot of less than six-thousand (6,000) square feet in area ... Lots shall have a width of not less than sixty (60) feet. ... a depth of not less than one-hundred (100) feet. ... not more than one (1) dwelling unit per lot ... gross floor area of such dwelling does not exceed fifty (50) percent of the total lot area ... building site coverage ... does not exceed thirty-five (35) percent of the total lot area ... gross floor area of less than eight-hundred (800) square feet.
Sections 10400-10403