I-1
Dimensional standards
Uses
Permitted by right16
- assembly
- building supply
- manufacturing
- processing
- electric generation
- junk yards
- salvage operations
- public utility facilities
- heavy equipment sales
- heavy equipment services
- storage
- transport stations
- retail sales and wholesaling when associated with permitted use
- one dwelling unit when in conjunction with industrial use
- child day care homes
- limited child day care homes
Conditional / special use3
Accessory1
Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Height
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for dwelling unitsDwelling unitOne independent home: its own kitchen, bathroom and entrance.35 ft
dwelling units, which shall not exceed thirty-five (35') feet.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for timber product manufacturing structures125 ft
No timber product manufacturing structure ... shall exceed 125 feet in height.
Other
- Side and rear yardYardThe open space left between a building and its lot line — the space a setback creates. setbackSetbackThe distance a building must be held back from a lot line. when adjacent to residentially zoned parcel10 ft
ten (10') feet for yards adjacent to a residentially zoned parcel.
- Site development review required for permitted uses
subject to site development review as set forth in Article 11.3
Signage
- Additional self-supporting sign with special use permitConditional useAllowed only after a discretionary approval — usually a public hearing and a board vote.200 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Subject to the issuance of a special use permit, one additional self-supporting sign structure shall be permitted with a total face area not to exceed 200 square feet.
- Maximum business sign face area200 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
total face area ... does not exceed ten (10%) percent of the building front square footage nor 200 square feet, whichever is less, for each street frontage treated separately, except that each frontage shall be allowed at least thirty-two (32) square feet.
From the ordinance
Minimum net lot area 10,000 sq ft; min width 60 ft; max coverage 70%; front yard 20 ft; side/rear none except 10 ft adjacent to residential; height 75 ft except dwelling 35 ft and timber 125 ft; signs limited to 10% of building front or 200 sq ft.