Extracted standards
12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum bracket extension8 in
The support brackets may not extend beyond the new structure by more than eight inches.
- Design resemblance
When a new small wireless facility support structure is a replacement for an existing structure or is in the line of existing structures of similar height and bulk, e.g., a replacement for an electric pole or a new faux streetlight, the structure shall be designed so as to resemble, as closely as practical, the form and type of the existing structure or the structures in the same line.
- Equipment color
All mounting brackets and wiring, cables, and conduits that are not located in a fully enclosed structure must be same color as, or otherwise demonstrated to match or blend with, the new structure on which they are mounted.
- Maximum equipment volume32 cuft
Must not exceed 32 cubic feet in volume.
- Ground equipment gross area in other areas500 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
does not exceed 12 feet in height and a total of 500 square feet in gross area.
- Ground equipment heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in other areas12 ft
When the related equipment is not located on property that meets subsection a., each provider is limited to a cabinet or structure which does not exceed 12 feet in height and a total of 500 square feet in gross area.
- Ground equipment heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in single-familySingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. residential areas5 ft
In public rights-of-way abutting single-family residential districts or areas in which attached or detached single-family dwellings are the predominant use or development pattern, each small cell facility is limited to one cabinet or structure that does not exceed five feet in height and a total of 70 cubic feet in volume.
- Ground equipment volume in single-familySingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. residential areas70 cuft
does not exceed five feet in height and a total of 70 cubic feet in volume.
- Minimum pole spacing in other areas100 ft
When located in all other areas, not less than 100 feet.
- Minimum pole spacing in single-familySingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. residential areas300 ft
When located in zoning districts that are zoned for single-family dwellings and are or areas in which attached or detached single-family dwellings are the predominant use or development pattern, not less than 300 feet.
- Screening requirement for ground equipment
The cabinets or equipment must be secured by a wall, berm, or evergreen hedge sufficient to screen it from view from the street, or with an eight-foot fence, wall, berm, or landscaping combination.
- Wiring securing
All wiring and cables must be firmly secured to the utility distribution or transmission pole or other support structure.
From the ordinance
Small wireless facility support structures may be considered either principal or accessory uses.