Extracted standards

5 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Bypass lane width10 ft

    All drive-through facilities shall be provided with a bypass lane with a minimum width of ten feet.

  • Drive-through lane width for two or more lanes10 ft

    Two or more lanes = Ten feet per lane.

  • Drive-through lane width for one lane12 ft

    One lane = 12 feet.

  • Stacking space requirements by use

    Financial institutions: 6 spaces for first window + 2 per additional; car wash: 3 per bay self-service, 5 per bay automated; fast food: 5 per window; other uses: 3 per window.

  • Minimum stacking space dimensions

    Each stacking space shall be a minimum of ten feet by 20 feet.

From the ordinance

Stacking spaces shall be provided for any use having a drive-through facility or areas having drop-off and pick-up areas. The following general standards shall apply to all stacking spaces and drive-through facilities...