Surry County Unincorporated, Virginia · General provision

Sec. 3-1401, 3-1402, 3-1403, 3-1404, 3-1405

Dimensional standards

Servicing

Applies near
Chesapeake Bay, James River
Geographic extent
Chesapeake Bay Preservation Areas (CBPAs) including Resource Protection Areas (RPAs) and Resource Management Areas (RMAs) within the James River Watershed

Extracted standards

15 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Environmental

  • Slope threshold for RMA feature15 pct

    Slopes in excess of 15 percent

  • A minor water quality impact assessment pertains only to land disturbance, development or redevelopment activity within a CBPA which causes no more than 5,000 square feet of land disturbance

  • Any development or redevelopment exceeding 2,500 square feet of land disturbance in the CBPA shall be accomplished through a plan of development process

  • Minimum replacement tree caliper2.5 in

    Replacement trees shall be a minimum two and one-half inches caliper measured six inches above the ground at the time of planting.

  • Minimum tree DBH to show on plan2 in

    All existing trees on the site two inches or greater in diameter at breast height (DBH) shall be shown on the plan

  • Tree replacement ratio2 ratio

    replacement of existing trees and other vegetation will be achieved at a ratio of two planted trees to one removed.

  • RPA buffer nutrient reduction40 pct

    The 100-foot RPA buffer shall be deemed to achieve a 75 percent reduction of sediments and a 40 percent reduction of nutrients.

  • RPA buffer sediment reduction75 pct

    The 100-foot RPA buffer shall be deemed to achieve a 75 percent reduction of sediments and a 40 percent reduction of nutrients.

  • RPA buffer width100 ft

    a buffer area not less than 100 feet in width located adjacent to and landward of the components listed in subsections A.1. through 4. above, and along both sides of any water body with perennial flow.

  • Agricultural activities may encroach into the landward 50 feet of the 100-foot wide buffer area when at least one agricultural best management practice...

  • RPA buffer encroachment landward limit for agriculturalAgricultureRaising crops or livestock, generally including the structures that serve them. activities with more BMPs75 ft

    Agricultural activities may encroach within the landward 75 feet of the 100-foot wide buffer area when agricultural best management practices which address erosion control, nutrient management, and pest chemical control, are being implemented on the adjacent land.

  • RPA buffer encroachment seaward limit50 ft

    The encroachment may not extend into the seaward 50 feet of the buffer area.

  • Septic pump-out frequency5 years

    All on-site sewage disposal systems not requiring VPDES permit shall be pumped out at least once every five years.

  • This submittal is not required for individual one- and two-family homes located on lots one acre or greater in size if the impervious cover is 16 percent or less of the total site area.

  • This submittal is not required for individual one- and two-family homes located on lots one acre or greater in size if the impervious cover is 16 percent or less of the total site area.

From the ordinance

The requirements contained herein establish the means to minimize erosion and sedimentation potential, reduce land application of nutrients and toxins, and maximize rainwater infiltration within the Chesapeake Bay Preservation Areas...
Sec. 3-1401, 3-1402, 3-1403, 3-1404, 3-1405