Surry County Unincorporated, Virginia · General provision

Sec. 4-517

Dimensional standards

lot requirementsSTREETMIN LOT AREA2,500 sq ftMAX DENSITY6 du/ac
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Uses

Permitted by right1

Extracted standards

4 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

From the ordinance

For townhouses for sale and similar attached development types, the development or project shall consist of at least ten dwelling units with no less than three and no more than six units contiguous to one another. Public water and public sewer service shall be provided. Overall project density shall not exceed six dwelling units per acre including public or commonly used rights-of-way constructed to serve the project. Each townhouse shall be erected or placed on a specifically designated land area or on a lot containing not less than 2,500 square feet. The minimum distance between any two unattached townhouse structures shall be 40 feet. The setback shall be increased to 60 feet if the townhouse structures are face to face.