Onancock, Virginia · General provision

Sec. 38-308

Dimensional standards

Servicing

Applies near
Chesapeake Bay
Geographic extent
All lands identified as Chesapeake Bay Preservation Areas as shown on the town zoning map, including resource protection areas, resource management areas, and intensely developed areas.

Extracted standards

17 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • achieve a 40 percent reduction in nonpoint source pollution from agricultural uses.

  • Buffer encroachment limit from water50 ft

    The encroachment may not extend into the seaward 50 feet of the buffer area.

  • Buffer nutrient reduction40 pct

    The 100-foot buffer area shall be deemed to achieve a 75 percent reduction of sediments and a 40 percent reduction of nutrients.

  • Buffer sediment reduction75 pct

    The 100-foot buffer area shall be deemed to achieve a 75 percent reduction of sediments and a 40 percent reduction of nutrients.

  • Buffer width100 ft

    A 100-foot buffer area of vegetation that is effective in retarding runoff, preventing erosion and filtering nonpoint source pollution from runoff shall be retained if present and established where it does not exist.

  • Environmental site assessment required

    An environmental site assessment shall be submitted as a component of, and in conjunction with, site plan approval.

  • Impervious cover shall be minimized consistent with the proposed use or type of development.

  • Minimum tree DBH for preservation6 in

    Existing trees over six inches in diameter at breast height (DBH) shall be preserved outside the construction footprint.

  • Any development or redevelopment in a Chesapeake Bay Preservation Area (CBPA) exceeding 2,500 square feet of land disturbance shall be accomplished through a plan of development process...

  • Post-development pollutant load limit

    For development, the post-development nonpoint source pollution runoff load shall not exceed the pre-development load, based on the calculated average impervious cover of 34 percent.

  • Redevelopment pollutant load reduction10 pct

    For sites within IDAs or other isolated redevelopment sites, the nonpoint source pollution load shall be reduced by at least ten percent.

  • Tree replacement ratio3 trees per tree removed

    replacement of existing trees and other vegetation will be achieved at a ratio of three planted trees to one removed.

  • Development in RPA restriction

    Development in RPAs may be allowed only if it is water-dependent, or it constitutes redevelopment; or it constitutes development or redevelopment within the intensely developed area.

  • Stormwater management plan contents

    A stormwater management plan shall contain maps, graphs, tables, narrative descriptions and citations to supporting references as appropriate to communicate information required by section 38-312(b).

  • Surety required for landscaping

    When the occupancy of a structure is desired prior to the completion of the required landscaping, stormwater management facilities, or other specifications of an approved plan, a certificate of occupancy may be issued only if the applicant provides to the town a form of surety satisfactory to the zoning administrator...

  • Tree protection barrier distance from drip line5 ft

    Prior to clearing or grading, suitable protective barriers, such as safety fencing, shall be erected five feet outside of the drip-line of any tree or stand of trees to be preserved.

  • Water quality impact assessment required

    A water quality impact assessment shall be required for any land disturbance within a resource protection area.

From the ordinance

The Chesapeake Bay Preservation Area Overlay District shall apply to all lands identified as CBPAs as designated by the town council and as shown on the town zoning map as the Chesapeake Bay Preservation Area Overlay District.