14-14
Dimensional standards
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum distance between ground and protruding blades15 ft
The minimum distance between the ground and any protruding blades utilized on a small wind energy tower shall be 15 feet, as measured at the lowest point of the arc of the blades.
- Minimum blade clearance above structures within 150 feet10 ft
The lowest point of the arc of the blade shall also be ten feet above the height of any structure within 150 feet of the tower base.
- Artificial lighting prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
A small wind energy system shall not be artificially lighted.
- SetbackSetbackThe distance a building must be held back from a lot line. from adjacent lots
A small wind energy system shall be set back from all adjacent lots or parcels of land a distance equal to at least 110 percent of the height of the tower, plus the blade length
- SetbackSetbackThe distance a building must be held back from a lot line. from inhabited dwelling on adjoining lots
and a distance equal at least to 150 percent of the tower height, plus blade length from any inhabited dwelling on all adjoining lots or parcels of land.
- Advertising signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
A small wind energy tower shall have no advertising sign, writing, or picture.
- Maximum tower heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.60 ft
A small wind energy tower shall have a maximum tower height of 60 feet.
From the ordinance
A small wind energy tower shall have a maximum tower height of 60 feet.