14-13
Dimensional standards
Extracted standards
14 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- WCF abandonment removal (days)180 days
A WCF and its accessory equipment shall be removed, at the owner's expense, within 180 days of cessation of use
- WCF co-location requirement (up to 120 ft)3 count
Each freestanding WCF up to 120 feet in height shall be engineered and constructed to accommodate no fewer than three co-located WCFs.
- WCF co-location requirement (121-150 ft)4 count
Each freestanding WCF that is 121 feet up to 150 feet in height shall be engineered and constructed to accommodate no fewer than four co-located WCFs.
- WCF co-location requirement (151+ ft)6 count
Each freestanding WCF that is 151 or more feet in height shall be engineered and constructed to accommodate no fewer than six WCFs.
- WCF equipment cabinet heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (visibility)3 ft
Equipment cabinets more than three feet in height shall not be visible from ground level.
- WCF landscape buffer width10 ft
landscape screening shall consist of a ten-foot wide buffer
- WCF landscape shrub spacing5 ft
evergreen shrubs capable of creating a continuous hedge and obtaining a height of at least five feet, plant five-feet on center
- WCF landscape tree spacing25 ft
planted with evergreen trees, minimum two inches caliper, 25-feet on center
- Maximum WCF heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (all districts)199 ft
not to exceed 199 feet
- Maximum WCF heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (R-1, R-2, R-3)125 ft
in R-1, R-2 and R-3 zoning districts the maximum height of a WCF shall be 125 feet.
- WCF mitigation max heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (pct of original)115 pct
The height of a mitigated WCF shall not exceed 115 percent of its original height.
- WCF setbackSetbackThe distance a building must be held back from a lot line. (breakpoint design)110 pct
the minimum setback shall be a distance equal to 110 percent of the distance from the highest point on the structure to the breakpoint level of the structure.
- WCF setbackSetbackThe distance a building must be held back from a lot line. (non-breakpoint design, >100 ft)110 pct
the minimum setback distance for any such structure more than 100 feet in height shall be equal to 110 percent of the height of the proposed support structure.
- WCF vacancy removal (days)60 days
A support structure which remains unoccupied by any antenna for a period of 180 consecutive days ("vacancy period") shall be removed within 60 days of the last day of the vacancy period
From the ordinance
The requirements set forth in this ordinance shall govern the location of WCFs installed in any zoning district.