Madison County Unincorporated, Virginia · General provision

Article 4, Sections 4.2 and 4.3

Dimensional standards

Servicing

Geographic extent
Applies to all special flood hazard areas in Madison County

Extracted standards

11 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Anchoring to prevent flotation

    New construction and substantial improvements shall be according to Section 3.1 of this ordinance and the VA USBC, and anchored to prevent flotation, collapse or lateral movement of the structure.

  • Flood-resistant materials

    New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

  • Minimize flood damage

    New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage.

  • Non-residential lowest floor elevation1 ft

    New construction or substantial improvement of any commercial, industrial, or non-residential building (or manufactured home) shall have the lowest floor, including basement, elevated to no less than one (1) foot above the base flood level. Buildings located in all A and AE zones may be floodproofed in lieu of being elevated...

  • On-site waste disposal

    On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding.

  • Residential lowest floor elevation1 ft

    New construction or substantial improvement of any residential structure (including manufactured homes) in Zones A and AE with detailed base flood elevations shall have the lowest floor, including basement, elevated to no less than one (1) foot above the base flood level.

  • Sewage system protection

    New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters.

  • Space below lowest floor

    In zones A and AE, fully enclosed areas, of new construction or substantially improved structures, which are below the regulatory flood protection elevation shall: 1. Not be designed or used for human habitation, but shall only be used for parking of vehicles, building access, or limited storage... 2. Be constructed entirely of flood resistant materials... 3. Include measures to automatically equalize hydrostatic flood forces...

  • Utility protection

    Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.

  • Water supply protection

    New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system.

Overlay

From the ordinance

New construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement... lowest floor elevated to no less than one foot above base flood level.
Article 4, Sections 4.2 and 4.3