Dimensional standards
Servicing
- Geographic extent
- County-wide
Extracted standards
3 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Pump island setbackSetbackThe distance a building must be held back from a lot line. from right-of-way (1-45 degrees)20 ft
a minimum of 20 feet from the street or roadway right-of-way when the pump island is situated at an angle of from one to 45 degrees to the roadway
- Pump island setbackSetbackThe distance a building must be held back from a lot line. from right-of-way (46-90 degrees)30 ft
a minimum of 30 feet from the street or roadway right-of-way when the pump island is situated at an angle of 46 to 90 degrees to the roadway
- Pump island setbackSetbackThe distance a building must be held back from a lot line. from right-of-way (parallel)12 ft
a minimum of 12 feet from the street or roadway right-of-way when the pump island is situated parallel to the roadway
From the ordinance
All appliances for dispensing gasoline installed outside of enclosed buildings shall be located either: (A) a minimum of 12 feet from the street or roadway right-of-way when the pump island is situated parallel to the roadway; (B) a minimum of 20 feet ... at an angle of from one to 45 degrees; or (C) a minimum of 30 feet ... at an angle of 46 to 90 degrees.