Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Number of copies12 sets
The applicant shall provide 12 sets of copies of the proposed site plan, and one additional set of reduced-size (11-inch x 17-inch) sheets.
- Minimum lettering heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.0.13 in
Lettering shall be no less than ⅛ inch or 2.54 mm in height.
- Minimum line weight0.01 in
Lettering and line weight shall be no less than 0.013 inches or 0.3302 mm.
- Minimum margin0.25 in
Margins shall be at least ¼ inch on all sides
- Maximum sheet size24 in
Each sheet of the site plan shall be between 8½ x 11 and 24 x 36 inches
- Minimum sheet size8.5 in
Each sheet of the site plan shall be between 8½ x 11 and 24 x 36 inches
- Site plan validity5 years
An approved final site plan shall be valid for a period of not less than five years from the date of approval thereof
From the ordinance
A site plan shall be prepared, signed and sealed by a professional architect, engineer, land surveyor or certified landscape architect licensed to practice in the Commonwealth of Virginia.