Lancaster County Unincorporated, Virginia · General provision

Article 23, Sections 23-1-2, 23-3-2, 23-4-1, 23-4-2, 23-4-3

Dimensional standards

Servicing

Applies near
FIRM/FIS
Geographic extent
All lands within Lancaster County identified as areas of special flood hazard on the Flood Insurance Rate Map (FIRM) and Flood Insurance Study (FIS) dated July 5, 2022.

Extracted standards

12 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Anchoring to prevent flotation

    New construction and substantial improvements shall be built according to this ordinance and the VA USBC, and anchored to prevent flotation, collapse, or lateral movement of the structure.

  • The total net area of all openings must be at least one square inch for each square foot of enclosed area subject to flooding.

  • Flood-resistant materials

    New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.

  • Accessory structures... shall be limited to no more than 600 square feet in total floor area.

  • The bottom of all required openings shall be no higher than one foot above the adjacent grade.

  • Minimum number of flood openings2 count

    Provide a minimum of two openings on different sides of each enclosed area subject to flooding.

  • On-site waste disposal systems

    On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding.

  • Opening coverings allowed

    Openings may be equipped with screens, louvers, or other opening coverings or devices, provided they permit the automatic flow of floodwaters in both directions.

  • Permit required for all development

    All uses, activities, and development occurring within any floodplain district, including placement of manufactured homes, shall be undertaken only upon the issuance of a permit.

  • Sanitary sewage systems

    New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters.

  • Utility and equipment protection

    Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.

  • Water supply systems

    New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system.

From the ordinance

These provisions shall apply to all privately and publicly owned lands within the jurisdiction of Lancaster County and identified as areas of special flood hazard... The Floodplain Districts described above shall be overlays to the existing underlying districts... All uses, activities, and development occurring within any floodplain district... shall be undertaken only upon the issuance of a permit.
Article 23, Sections 23-1-2, 23-3-2, 23-4-1, 23-4-2, 23-4-3