King George County Unincorporated, Virginia · General provision

Section 5-3-16

Dimensional standards

Servicing

Geographic extent
Applies to all Special Flood Hazard Areas (SFHA) and floodway areas within the county.

Extracted standards

19 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Anchoring requirement

    Be anchored to prevent floatation.

  • Elevation of electrical and mechanical equipment

    Have electrical service and mechanical equipment elevated to or above the base flood elevation.

  • Flood damage-resistant materials

    Be constructed with flood damage-resistant materials below the base flood elevation.

  • There shall be a minimum of two flood openings on different sides of each enclosed area; if a building has more than one enclosure below the lowest floor, each such enclosure shall have flood openings on exterior walls. The total net area of all flood openings shall be at least 1 square inch for each square foot of enclosed area (non-engineered flood openings), or the flood openings shall be engineered flood openings that are designed and certified by a licensed professional engineer to automatically allow entry and exit of floodwaters; the certification requirement may be satisfied by an individual certification, or an Evaluation Report issued by the ICC Evaluation Service, Inc. The bottom of each flood opening shall be 1 foot or less above the higher of the interior floor or grade, or the exterior grade, immediately below the opening. Any louvers, screens, or other covers for the flood openings shall allow the automatic flow of floodwaters into and out of the enclosed area.

  • Be limited to no more than 600 square feet in total floor area.

  • Not be used for human habitation; be useable only for parking of vehicles or limited storage.

  • Drainage facilities flood design

    All storm drainage facilities shall be designed to convey the flow of surface waters without damage to persons or property. The systems shall ensure drainage away from buildings and on-site waste disposal systems.

  • Existing structure conformity

    Any structure or use of a structure or premises must be brought into conformity with these provisions when it is changed, repaired, or improved unless one of the following exceptions is established before the change is made: ...

  • Flexible skirting exemption

    Foundation enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require openings.

  • The total net area of all openings must be at least 1 square inch for each square foot of enclosed area subject to flooding.

  • The bottom of all required openings shall be no higher than 1 foot above the adjacent grade.

  • Flood opening coverings

    Openings may be equipped with screens, louvers, or other opening coverings or devices, provided they permit the automatic flow of floodwaters in both directions.

  • Minimum number of flood openings2 openings

    Provide a minimum of two openings on different sides of each enclosed area subject to flooding.

  • Maximum consecutive days for recreational vehicle180 days

    Be on the site for fewer than 180 consecutive days and be fully licensed and ready for highway use.

  • Sanitary sewer flood design

    All new or replacement sanitary sewer facilities and private package sewage treatment plants, including all pumping stations and collector systems, shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into the flood waters.

  • Streets and sidewalks flood design

    Streets and sidewalks should be designed to minimize their potential for increasing and aggravating the levels of flood flow. Drainage openings shall be required to sufficiently discharge flood flows without unduly increasing flood heights.

  • Utilities flood design

    All utilities, such as gas lines, electrical and telephone systems being placed in flood-prone areas should be located, elevated where possible, and constructed to minimize the chance of impairment during a flooding occurrence.

  • Variances shall be issued only upon a showing of good and sufficient cause; determination by the BZA that failure to grant the variances would result in exceptional hardship; determination by the BZA that the variance will be the minimum required to provide relief; and after the BZA has determined that the granting of such variance will not result in unacceptable or prohibited increases in flood height, additional threats to public safety, extraordinary public expense, etc.

  • Water facilities flood design

    All new or replacement water facilities shall be designed to minimize or eliminate infiltration of flood waters into the system and be located and constructed to minimize or eliminate flood damages.

From the ordinance

Accessory structures in the SFHA shall comply with the elevation requirements and other requirements of Section 5-3-16 or, if not elevated or dry floodproofed, shall: ...
Section 5-3-16