Sec. 24-4306.C
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Centralized trash and recyclables collection
Apartment buildings must provide centralized collection of trash and recyclable materials adequate to serve the number of dwelling units and meeting the requirements of Sec. 24-4428, Accessory Recycling and Refuse Collection Area, Outdoor, and Sec. 24-5103.G, Access to Shared Facilities.
- HVAC and mechanical equipment screening
All ground level and rooftop HVAC and mechanical equipment must be screened from view from the property lines at ground level. Screening must consist of materials used in the principal building's front façade or other materials approved by the Planning Director as allowing the screened area to blend in with its surroundings, supplemented with landscaping.
- Maximum units per multifamilyMultifamily dwellingA building of four or more dwelling units. Where zoning is most restrictive. building in RTH6 units
In the RTH District, the number of dwelling units in a multifamily building must not exceed six.
- Public water and sewer required
All multifamily dwellings must be served by public water and sewer.
- Stormwater facility design as amenity
Any stormwater management facility must be designed and utilized as a water feature amenity or designed and landscaped in a manner consistent with the surrounding development.
- Underground utilities required
Except for junction boxes, meters, and pre-existing overhead utility lines, all utilities serving multifamily dwellings must be underground, except where the Planning Director determines that underground utilities are not practical or desirable for technical or environmental reasons. Junction boxes must be screened from view from the property lines at ground level with approved fencing or landscaping.
Parking
- Additional RV parking percentage5 pct
In addition to the parking required by Sec. 24-5110, Minimum Number of Off-Street Parking Spaces, an additional five percent of the minimum number of required parking spaces must be provided for recreational vehicles. This parking area must be located in a separate, designated area, must not be located in front of units, and must be landscaped in accordance with Sec. 24-5312, Parking Lot Landscaping. The Planning Director may reduce or waive this requirement where full compliance would be impractical or unnecessary due to the design and layout of the site or the specific type of dwelling units proposed.
From the ordinance
All ground level and rooftop HVAC and mechanical equipment must be screened from view from the property lines at ground level. ... All multifamily dwellings must be served by public water and sewer. In the RTH District, the number of dwelling units in a multifamily building must not exceed six. ... an additional five percent of the minimum number of required parking spaces must be provided for recreational vehicles.