Dimensional standards
Height & bulk
Servicing
- Geographic extent
- Applies to properties within the boundaries of the Coliseum Central Business Improvement DistrictZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. (CCBID), but not to residentially zoned or developed properties.
Uses
Permitted by right17
- micro-brewery/distillery/winery
- live entertainment 1 (with conditions)
- mental health/substance abuse treatment facility (only in C-2 base zoning)
- retail sales, services, and office uses (enclosed except for listed exceptions)
- car wash, self-service or automated
- gas station
- motorcycle sales
- outdoor dining
- parking lots
- vehicle sales, new
- vehicle storage
- special event permit uses
- seasonal sales
- permanent outdoor sales, displays, and storage
- food truck host sites
- outdoor play areas associated with day care
- outdoor recreation areas
Prohibited18
- boarding house
- funeral home
- mobile/manufactured home park and subdivision
- pawnshop
- rooming house
- sign painting shop
- tattoo parlor
- Turkish bath
- detention facility
- group home 2
- halfway house
- juvenile residence
- orphanage
- shelter
- shooting range, trap or skeet
- boathouse, pier, dock, ramp; commercial
- marina
- storage facility 1, 2, and 3
Extracted standards
12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Fencing & walls
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. fence materials
the use of chain link fencing, electrified fencing, barbed wire or razor wire is expressly prohibited.
Lighting
- Maximum illumination on building facades5 foot-candles
Illumination levels on any vertical surface or angular roof shall not exceed five (5.0) foot-candles.
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of lighting fixtures in exterior sales/display areas25 ft
Fixtures shall be mounted no more than twenty-five (25) feet above grade
- Maximum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of lighting poles in parking areas40 ft
Lighting poles and fixtures shall be no more than forty (40) feet above grade
- Maximum uniformity ratio for parking lighting4 ratio
uniformity ratio (ratio of average to minimum illuminance) shall be no greater than 4:1
- Minimum light level in parking areas0.5 foot-candles
provide a minimum light level of one-half (0.5) foot-candles
Other
- Maximum percentage of floor area for storage50 pct
No more than fifty (50) percent of the floor area of any building shall be used for the storage of merchandise.
- Minimum green area within paved parking surface10 pct
At least ten (10) percent of the paved parking surface, including drive aisle and access.
- Minimum green area as percentage of total site area10 pct
At least ten (10) percent of the total site area, or the percentage required by the parking setbacks and parking lot green area requirements, whichever is greater.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. primary exterior finishes
In no instance shall EIFS, corrugated metal, pre-engineered metal or exposed metal wall systems be used as primary exterior finish.
- Communication towers not allowed between buildings and right-of-way
Noncommercial and commercial communication towers, satellite dishes and transmission antennas (with exception of building mounted antennas) shall not be located between any buildings and an existing or proposed public right-of-way.
- Use permit required for tall or commercial towers75 ft
All noncommercial communication towers in excess of seventy-five (75) feet in height and all commercial communication towers shall be subject to securing a use permit.
From the ordinance
Permitted uses shall be defined by the base zoning ... with the following modifications: ... At least ten (10) percent of the total site area ...