HRC-3
Dimensional standards
Height & bulk
Servicing
- Geographic extent
- Boundaries as per official zoning map
Extracted standards
21 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Bollard heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for driveways and walkways3.5 ft
All lighting in driveways, pedestrian walkways and plazas will be achieved with bollards not exceeding three and one-half (3½) feet in height and/or low surface mounted fixtures.
- Lighting color corrected for true white, no high/low pressure sodium
All lighting will be color corrected for true white, with allowances for modest amounts of blue or green. ... The use of high and low pressure sodium sources will not be allowed and use of incandescent sources will be limited to building entrances only.
- Parking area lighting pole heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.35 ft
Lighting in parking areas and truck courts will be pole mounted fixtures with a height of thirty-five (35) feet and provide a minimum lighting level of one-half (½) foot-candles.
Other
- Green space strip between buildings and parking areas10 ft
A green space strip at least ten (10) feet wide shall be provide between buildings and parking areas except at plazas, points of entry to the building, and loading dock areas
- Primary building materials monochromatic earth tones; bright colors only for accents
Primary building materials shall be monochromatic (preferably earth tones). Bright overall colors shall not be permitted as primary building colors, but may be used for accents.
- Dumpsters visible from boundaries or within 50 ft of north/west boundaries must be enclosed on three sides50 ft
All dumpsters visible from the eastern or southern district boundaries, or within fifty (50) feet of the northern or western district boundaries, shall be enclosed on three (3) sides by an opaque fence.
- Exterior walls must be brick, masonry, precast concrete, metal panels, granite, glass, or similar
All exterior building materials shall result in permanent and durable construction. Except for interior courtyards, all exterior walls shall be constructed of brick or other high quality finished masonry, precast concrete panels, high quality metal panels, granite, glass, or materials of similar quality and durability.
- Fences adjacent to Big Bethel Road at westernmost edge of vegetated berm
Fences adjacent to the Big Bethel Road right-of-way shall be located at the westernmost edge of the vegetated berm required under the provisions of the 'City of Hampton Landscape Guidelines'.
- Green space island width when two rows abut24 ft
Whenever two (2) rows of parking spaces abut, the required green space islands shall be a minimum of twenty-four (24) feet wide.
- All construction must be approved by IDA/DRC prior to site plan approval
All construction within the HRC-3 District must be approved by the Hampton Industrial Development Authority's Design Review Committee (IDA/DRC) prior to site plan approval.
- Improvement setbackSetbackThe distance a building must be held back from a lot line. along Big Bethel Road50 ft
The fifty (50) foot improvement setback along Big Bethel Road shall be retained as green space
- Improvement setbackSetbackThe distance a building must be held back from a lot line. along North Park Lane and Interstate 6420 ft
The twenty (20) foot improvement setbacks along North Park Lane and Interstate 64 shall be retained as green space
- Loading docks and truck courts screened per Landscape Guidelines
Loading docks and truck courts shall be screened in accordance with the 'City of Hampton Landscape Guidelines'.
- Maximum total lot coverageLot coverageThe share of a lot that buildings may cover, as a percentage. for districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.80 pct
Total lot coverage within the HRC-3 District shall not exceed eighty (80) percent of the total district area.
- Maximum individual lot coverageLot coverageThe share of a lot that buildings may cover, as a percentage. if districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. coverage maintained90 pct
The total lot coverage on any individual lot may be as high as ninety (90) percent of the individual lot area, so long as the district lot coverage is maintained at or below eighty (80) percent.
- Maximum length of parking row without green space island144 ft
No row of parking spaces shall exceed one hundred forty-four (144) feet in length without a green space island. Such islands shall be a minimum of twelve (12) feet wide.
- Minimum green area for districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.20 pct
A minimum of ten (10) percent of each lot and twenty (20) percent of the district area shall be retained as green space for trees, shrubs and turf.
- Minimum green area per lot10 pct
A minimum of ten (10) percent of each lot and twenty (20) percent of the district area shall be retained as green space for trees, shrubs and turf.
- Outdoor storage screened per City of Hampton Landscape Guidelines
Outdoor material and equipment storage shall be screened in accordance with the 'City of Hampton Landscape Guidelines'.
- All owners must belong to property owners' association
All owners of property within the HRC-3 District shall belong to a property owners' association.
- Green area in parking lots with 30+ cars10 pct
At least ten (10) percent of any parking lot designed for thirty (30) or more cars shall be retained as green space
From the ordinance
Buildings shall be a maximum of fifty-five (55) feet in height. Total lot coverage within the HRC-3 District shall not exceed eighty (80) percent of the total district area.