Dimensional standards
Servicing
- Applies near
- flood zones
- Geographic extent
- Applies to all A1-30, AE, AH, AO flood zones.
Extracted standards
5 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Flood openings
Minimum two openings on different sides, total net area at least 1 sq inch per sq ft, bottom no higher than 1 ft above grade.
Manufactured homes must be elevated to design flood elevation and anchored.
- Non-residential floodproofing
Non-residential buildings in A1-30, AE, AH zones may be floodproofed if watertight and certified by engineer.
- Space below lowest floor
Fully enclosed areas below regulatory flood protection elevation shall not be used for habitation, only parking, access, storage.
- Subdivision standards
Subdivision proposals must minimize flood damage, have public utilities, adequate drainage, and base flood elevation data.
From the ordinance
Non-residential buildings located in all A1-30, AE, and AH zones may be flood-proofed in lieu of being elevated...