Essex County Unincorporated, Virginia · General provision

Section 36.701(b)

Extracted standards

7 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Contour interval2 ft

    contours at vertical intervals of not more than two feet

  • Boundary survey closure2,500 ratio

    field error of closure within the limit of one in two thousand five hundred (1' in 2,500')

  • Preliminary plat scale100 ft/inch

    scale of not more than 100 feet to the inch

  • Preliminary plat sheet size

    drawn on sheets twenty-four by thirty-six inches (24" x 36") (preferred) or thirty by forty-two inches (30" x 42") (maximum)

  • Spot elevation for low slope3 pct

    In cases where the land has less than 3 percent slope, spot elevation shall be required.

  • Utilities within 300 feet300 ft

    Location, width, and names of all existing, proposed utility right-of-way, parks, cemeteries, permanent buildings and bridges located within 300 feet of the subdivision

  • Zoning information within 300 feet300 ft

    Zoning on and within 300 feet of the subdivision.

From the ordinance

The preliminary plat shall be prepared by a qualified professional... scale of not more than 100 feet to the inch... boundary survey with a field error of closure within the limit of one in two thousand five hundred (1' in 2,500')...