Dimensional standards
Housing
Uses
Permitted by right22
- Communication and telecommunications centers
- Flex industrial use
- Fire, police, rescue stations
- Food production, packaging, packing, and canning
- Manufacture, processing, fabrication, assembly and/or storage of products
- Marinas, docks, wharves, and marina related businesses & industry
- Medical care facility, outpatient only
- Offices—administrative, business, professional, and telecommunication
- Outdoor storage (with landscaping)
- Park, plaza, or natural area
- Parking structure
- Post office, drop off and pick up, mail courier and parcel services
- Public utility service center, without outdoor storage
- Recording studio
- Research, experimental testing or development activities
- Restaurant, indoor and outdoor (excluding drive-through), restaurant/brewery
- Training center (excluding rehabilitation and institutional facilities)
- Utility installations
- Utility substations (with landscaping)
- Warehousing facility (excluding mini-storage)
- Water storage tank
- Wholesale trade establishment
Conditional / special use7
- Structures, other than buildings, exceeding 50 feet
- Buildings over 40 feet but equal or less than 50 feet or structures up to 75 feet if set back 125 additional feet
- Hotels
- Boatels
- Utility generating plant and transmission facilities using renewable energy sources
- Indoor recreational, business
- Any other compatible use
Accessory1
Extracted standards
12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Exterior lighting
All exterior lighting shall comply with section 32-94 'Outdoor Lighting'.
Noise
- Noise prohibition
No outside loudspeakers, intercoms, paging systems, whistles, horns, bells, or signals audible outside any buildings shall be allowed.
Other
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. when adjoining C districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.50 ft
When a zoning lot within the Harbor—Light Industrial District adjoins an Accawmacke Plantation PUD C district, a 50 foot natural buffer is required.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. when adjoining CO100 ft
When a zoning lot within the Harbor—Light Industrial District adjoins an Accawmacke Plantation PUD CO land use classification, a 100 foot natural buffer is required.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. when adjoining residential200 ft
Where the Harbor—Light Industrial District adjoins the R (residential) zoning districts within the Accawmacke PUD or CO land use classifications or C districts within the Accawmacke PUD, buffer yards are required... 200 feet natural buffer for R districts.
- Dust, smoke, noxious odors
No dust, smoke, or noxious odors shall be released from any structure, building, or equipment.
- Landscape screening
Buffer yard shall be landscaped with Category III landscape screening, width at least 100 feet for R, 50 feet for CO and C.
- Loading facilities distance from C75 ft
No loading facilities within 75 feet of C district.
- Loading facilities distance from CO100 ft
No loading facilities within 100 feet of CO land use classification.
- Loading facilities distance from residential200 ft
No loading facilities, loading docks, or loading bays shall be permitted within 200 feet of any zoning district that permits residential.
- Outside storage prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
No outside storage of parts, materials, fossil fuels, raw materials, or petroleum shall be permitted.
Parking
- Drive and parking setbackSetbackThe distance a building must be held back from a lot line. from ROW20 ft
No drive or parking area shall be located closer than 20 feet from any public right-of-way line.
From the ordinance
The following uses are permitted by right... (d) Conditional uses... (g) Additional development requirements...