Essex County Unincorporated, Virginia · General provision

Section 36.701

Extracted standards

6 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Maximum field error of closure2,500 ratio

    a field error of closure within the limit of one in two thousand five hundred (1' in 2,500')

  • Maximum contour interval2 ft

    contours at vertical intervals of not more than two feet.

  • Maximum plat scale100 ft/in

    at a scale of not more than 100 feet to the inch.

  • Maximum plat sheet size30 in

    or thirty by forty-two inches (30" x 42") (maximum).

  • Preferred plat sheet size24 in

    drawn on sheets twenty-four by thirty-six inches (24" x 36") (preferred)

  • Number of lots requiring preliminary plat50 lots

    All proposed major subdivisions involving more than 50 lots must submit a preliminary plat for approval.

From the ordinance

All proposed major subdivisions involving more than 50 lots must submit a preliminary plat for approval.
Section 36.701