Section 36.555
Dimensional standards
Lot
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum conveyance line easement width15 ft
Easements are required for conveyance lines of not less than 15 feet in width for all sewage conveyance lines
- Minimum conveyance line depth24 in
Conveyance lines shall be installed to a minimum depth of 24 inches.
- Minimum separation between drain fields and property lines10 ft
the area for each drain field shall be at least 10 feet from all other drain fields and 10 feet from the property lines of the subject lot
- Maximum lot areaMinimum lot areaThe smallest parcel on which the district allows anything to be built. requiring public/central water21,500 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Every subdivision, condominium or cluster development containing any lots of less than 21,500 square feet shall be provided with either a public or centralized water system
- Maximum number of lots with remote septic in minor subdivisions1 count
No more than one lot within any minor subdivision shall be allowed to utilize a remote system.
- Maximum percentage of lots with remote septic in major subdivisions20 pct
No more than 20 percent of the lots within any major subdivision shall be permitted to utilize a remote system.
- Maximum lot areaMinimum lot areaThe smallest parcel on which the district allows anything to be built. for which individual septic is prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.21,500 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
The Agent shall not approve the use of individual septic systems for any subdivision containing lots of less than 21,500 square feet.
- Minimum utility easement width16 ft
Easements of not less than 16 feet in width shall be provided for water, sewer, power lines and other utilities
From the ordinance
Easements of not less than 16 feet in width shall be provided for water, sewer, power lines and other utilities in the subdivision when required by the Agent. Every subdivision, condominium or cluster development containing any lots of less than 21,500 square feet shall be provided with either a public or centralized water system... The Agent shall not approve the use of individual septic systems for any subdivision containing lots of less than 21,500 square feet.