Essex County Unincorporated, Virginia · General provision

Section 36.477

Extracted standards

8 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Lighting

  • Canopy lighting recessed

    Light fixtures under any canopy shall be recessed into the canopy ceiling with a flat lens to prevent glare.

  • Full cutoff required

    Each outdoor luminaire subject to these outdoor lighting requirements shall be a full cutoff luminaire.

  • Light aimed inward

    all lighting shall be aimed and controlled such that directed light is directed inward to the property and confined to the object intended to be illuminated.

  • Maximum color temperature3,000 K

    All exterior lights shall be 3,000 Kelvin light color temperature or less.

  • Light fixtures in parking lots shall not be more than 20 feet in height in the Business Districts, High Density Residential District, and no more than 30 feet in height in the Industrial Districts.

  • Light fixtures in parking lots shall not be more than 20 feet in height in the Business Districts, High Density Residential District, and no more than 30 feet in height in the Industrial Districts.

  • No reflection to streets

    Lighting for buildings, signs, accessways, and parking areas shall be so arranged as not to reflect toward public streets or cause any annoyance to surrounding property owners or residents.

  • Preferred light types

    High-pressure sodium vapor or light emitting diode (LED) lights shall be the preferred type of exterior site lighting.

From the ordinance

Each outdoor luminaire subject to these outdoor lighting requirements shall be a full cutoff luminaire.
Section 36.477