Section 36.404
Dimensional standards
Extracted standards
16 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Battery storage dwelling setbackSetbackThe distance a building must be held back from a lot line.500 ft
The minimum setback for any battery storage units shall be 500 feet from any existing dwelling.
- Large-scale solar dwelling setbackSetbackThe distance a building must be held back from a lot line.150 ft
Facilities shall setback a minimum of 150 feet from any existing dwellings.
- Large-scale solar maximum area50 acresacre43,560 square feet — about the size of an American football field without the end zones.
The maximum area of a large-scale solar energy facility or PPA solar energy facility shall be less than 50 contiguous acres.
- Maximum solar building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.15 ft
The maximum height of principal buildings and accessory buildings shall be 15 feet as measured from the finished grade
- Maximum site gradingGrading (cut & fill)Reshaping land by removing earth (cut) or adding it (fill), often capped by volume.50 pct
no site shall be graded more than 50 percent of the site surface area.
- Maximum solar noise at dwelling50 dBA
or 50 dBA as measured at the nearest neighboring inhabitable building.
- Maximum solar noise at property line65 dBA
a utility-scale solar energy facility shall not produce a noise level that exceeds 65 dBA as measured at the property line
- Maximum solar panel heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.10 ft
The maximum height of the lowest edge of the photovoltaic panels shall be 10 feet as measured from the finished grade.
- Maximum slope for solar panels10 pct
PV solar panels and any associated equipment shall not be located on slopes 10 percent or greater
- Solar security fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.8 ft
The facilities shall be enclosed by security fencing a minimum of eight (8) feet in height
- Utility-scale solar buffer width100 ft
a buffer zone at least 100 feet wide that shall be landscaped with a minimum of two staggered rows of eight (8)-foot tall evergreen trees
- Utility-scale solar maximum area500 acresacre43,560 square feet — about the size of an American football field without the end zones.
the maximum area shall be less than 500 acres
- Utility-scale solar minimum area2 acresacre43,560 square feet — about the size of an American football field without the end zones.
The minimum area of a utility-scale solar energy facility shall be two (2) acres
- Utility-scale solar property line setbackSetbackThe distance a building must be held back from a lot line.150 ft
The minimum setback for utility-scale solar facilities to property lines shall be 150 feet.
- Utility-scale solar Rappahannock River setbackSetbackThe distance a building must be held back from a lot line.1 miles
Utility-scale solar facilities shall be located a minimum of 1 mile outside the banks of the Rappahannock River.
- Utility-scale solar town boundary setbackSetbackThe distance a building must be held back from a lot line.3 miles
Utility-scale solar energy facility shall be located at least three miles from a town boundary.
From the ordinance
The minimum area of a utility-scale solar energy facility shall be two (2) acres, and the maximum area shall be less than 500 acres