Covington, Virginia · General provision

Article III, Section 3.1.A.6

Dimensional standards

Servicing

Geographic extent
Areas designated as VE or V on the FIRM, extending from offshore to the inland limit of a primary frontal dune along an open coast or other areas subject to high velocity waves.

Extracted standards

6 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Breakaway walls

    All new construction and substantial improvements shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood-lattice work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purpose of this Section, a breakaway wall shall have a design safe loading resistance of not less than 10 and no more than 20 pounds per square foot.

  • Elevation on pilings or columns

    All new construction and substantial improvements in Zones V and VE, including manufactured homes, shall be elevated on pilings or columns so that: (1) The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the base flood level plus eighteen (18) inches if the lowest horizontal structural member is parallel to the direction of wave approach or elevated at least two feet above the base flood level if the lowest horizontal structural member is perpendicular to the direction of wave approach; and (2) The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components.

  • Enclosed space below lowest floor

    The enclosed space below the lowest floor shall be used solely for parking of vehicles, building access, or storage. Such space shall not be partitioned into multiple rooms, temperature-controlled, or used for human habitation. The enclosed space shall be less than 300 square feet.

  • Engineer certification

    A registered professional engineer or architect shall develop or review the structural design, specifications and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of Article III, Section A.6.a.

  • The use of fill for structural support of buildings is prohibited.

  • The man-made alteration of sand dunes, which would increase potential flood damage, is prohibited.

From the ordinance

All new construction and substantial improvements in Zones V and VE, including manufactured homes, shall be elevated on pilings or columns so that: (1) The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the base flood level plus eighteen (18) inches if the lowest horizontal structural member is parallel to the direction of wave approach or elevated at least two feet above the base flood level if the lowest horizontal structural member is perpendicular to the direction of wave approach...
Article III, Section 3.1.A.6