Claremont, Virginia · General provision

Sec. 3-1516(A)6

Dimensional standards

Servicing

Geographic extent
Coastal high hazard areas extending from offshore to the inland limit of a primary frontal dune along an open coast, shown as VE or V on FIRM

Extracted standards

8 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Anchoring to resist flotation, collapse, and lateral movement

    The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components.

  • Breakaway walls or free of obstruction below lowest floor

    All new construction and substantial improvements shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood-lattice work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system.

  • Elevation on pilings or columns18 inches

    The bottom of the lowest horizontal structural member of the lowest floor ... is elevated to or above the base flood level plus 18 inches if the lowest horizontal structural member is parallel to the direction of wave approach or elevated at least one foot above the base flood level if the lowest horizontal structural member is perpendicular to the direction of wave approach

  • The enclosed space below the lowest floor shall be used solely for parking of vehicles, building access, or storage. Such space shall not be partitioned into multiple rooms, temperature-controlled, or used for human habitation. The enclosed space shall be less than 300 square feet.

  • Engineer or architect certification required

    A registered professional engineer or architect shall develop or review the structural design, specifications and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice

  • The use of fill for structural support of buildings is prohibited.

  • New construction landward of mean high tide

    All new construction shall be located landward of the reach of mean high tide.

  • The man-made alteration of sand dunes, which would increase potential flood damage, is prohibited.

From the ordinance

All new construction and substantial improvements in Zones V and VE ... shall be elevated on pilings or columns so that: The bottom of the lowest horizontal structural member of the lowest floor ... is elevated to or above the base flood level plus 18 inches if the lowest horizontal structural member is parallel to the direction of wave approach or elevated at least one foot above the base flood level if the lowest horizontal structural member is perpendicular to the direction of wave approach
Sec. 3-1516(A)6