Dimensional standards
Height & bulk
- Minimum landscaping
- 3%
Extracted standards
152 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Landscaping & trees
- Minimum landscaping surround for ground-mounted signs3 ft
All non-temporary ground-mounted or monument signs shall be installed with a minimum surround of three feet of regularly maintained floral and shrubbery landscaping in every direction.
Signage
- Double-faced sign area measured on one side45 degrees
The permitted area of a double-faced sign shall be considered to be the area on one side only. If one face contains a larger sign area than the other, the larger face shall be used in calculating the sign area. A double-faced sign must have an internal angle between its two faces of no more than 45 degrees.
- Minimum electronic changeable copy message duration4 sec
Any portion of the electronic changeable copy sign message must have a minimum duration of four seconds and must be a static display.
- Minimum electronic graphic display image duration20 min
Any portion of the electronic graphic display sign image must have a minimum duration of twenty minutes and must be a static display.
- Animation, flashing, scrolling prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. on electronic signs
shall not contain any animation, flashing, scrolling, or other movement;
- Audio and pyrotechnics prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. with electronic signs
Audio speakers or any form of pyrotechnics are prohibited in association with a changeable copy or electronic sign.
- Automatic dimmer required on electronic signs
The electronic sign shall be equipped with an automatic dimmer that adjusts the brightness of the sign based on ambient light conditions;
- Maximum electronic sign brightness (day)5,000 nits
The maximum brightness of an electronic sign shall not exceed 5,000 nits during daylight hours
- Maximum electronic sign brightness (night)500 nits
and 500 nits during nighttime hours (from sunset to sunrise);
- Maximum number of words on electronic sign10 words
The text of the sign must be limited to ten words to allow passing motorists to read the entire copy with minimal distraction.
- Minimum electronic sign message duration8 sec
The message on an electronic sign shall remain static for a minimum of eight seconds
- Movement prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. on electronic signs
No portion of the electronic sign message or image may flash, scroll, twirl, change color, fade in or out or in any manner imitate movement.
- Electronic sign must be contained within a monument sign
The electronic sign must be contained within, or as part of, a monument sign;
- Electronic signs must be turned off at close of business
All electronic message signs must be turned off at the close of business.
- Electronic sign orientation setbackSetbackThe distance a building must be held back from a lot line. from residential lot150 ft
When located within one hundred and fifty feet of a residentially-used lot in a residential district, any part of the electronic sign must be oriented so that no portion of the sign face is visible from an existing or permitted principal structure on that lot.
- Electronic sign repair timeframe after notice30 days
any malfunctioning or non-functioning portion of the sign shall be repaired or replaced within thirty days of written notice from the town.
- Minimum separation between electronic signs35 ft
Electronic signs must be separated from other electronic signs by at least 35 feet.
- Electronic sign setbackSetbackThe distance a building must be held back from a lot line. from residential districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2. boundary100 ft
The leading edge of the electronic sign must be a minimum distance of one-hundred feet from any abutting residential district boundary;
- Electronic sign setbackSetbackThe distance a building must be held back from a lot line. from street right-of-way10 ft
The leading edge of the electronic sign must be a minimum distance of ten feet from any street right-of-way;
- Electronic sign must use a single color
The message or display must use a single color.
- Flag pole setbackSetbackThe distance a building must be held back from a lot line. from service drive, travel lane, or street5 ft
no freestanding pole shall be erected in the public right-of-way nor be within five (5) feet of a service drive, travel lane or adjoining street.
- Maximum for-sale sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. on high-speed roads8 ft
when the sign abuts a road with a speed limit greater than twenty-five miles per hour not more than one sign with a total area of up to thirty two square feet and a maximum height of eight feet.
- Maximum for-sale sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. on low-speed roads6 ft
On any property for sale or rent, not more than one sign with a total area of up to twelve square feet and a maximum height of six feet when the sign abuts a road with a speed limit of twenty-five miles per hour or less
- Freestanding sign setbackSetbackThe distance a building must be held back from a lot line. from street right-of-way0.5 ratio
all freestanding signs shall be set back from any street right-of-way at least half the height of the sign.
- Maximum illuminated sign intensity (day)85 pct
The intensity of light allowed for all illuminated signs shall be eighty-five percent by day
- Maximum illuminated sign intensity (night)50 pct
and fifty percent at night.
- Multiple tenant sign area limited to single tenant maximum
In instances where there are multiple tenants or users on a property or in a building, allowable sign area for all parties shall not exceed the maximum sign area computed as if there were a single tenant or user.
- Noncommercial signs in residential districts follow temporary sign standards
Noncommercial signs in residential districts shall be subject to the same standards as temporary signs in residential districts, as set forth in Section 10.32.080 of this article.
- Noncommercial message substitution allowed
Wherever this article permits a sign with commercial content, noncommercial content is also permitted subject to the same requirements
- Noncommercial message substitution allowed
Wherever this article permits a sign with commercial content, noncommercial content is also permitted subject to the same requirements of size, color, illumination, movement, materials, location, height and construction.
- Noncommercial message substitution in residential districts
Any sign permitted by this article may contain a noncommercial message in lieu of a commercial message, provided that the sign otherwise complies with all applicable provisions of this article, including but not limited to size, height, setback, illumination, and location requirements.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign abandonment period2 years
a nonconforming sign structure shall be removed if the use to which it is accessory has not been in operation for a period of two years or more.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign abandonment period2 years
a nonconforming sign structure shall be removed if the use to which it is accessory has not been in operation for a period of two years or more.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign alteration prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Nonconforming signs shall not be extended or structurally reconstructed or altered in any manner
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign alteration prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Nonconforming signs shall not be extended or structurally reconstructed or altered in any manner, except a sign face may be changed so long as the new face is equal to or reduced in height and/or sign area.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign converted to conforming loses status
A nonconforming sign which is changed to becoming conforming or is replaced by a conforming sign shall no longer be deemed nonconforming, and thereafter such sign shall be in accordance with the provisions of this article.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign damage restoration threshold50 pct
A nonconforming sign that is destroyed or damaged by any casualty to an extent not exceeding fifty percent of its area may be restored within two years
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign damage restoration threshold50 pct
A nonconforming sign that is destroyed or damaged by any casualty to an extent not exceeding fifty percent of its area may be restored within two years after such destruction or damage but shall not be enlarged in any manner.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign enlargement prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
No nonconforming sign shall be enlarged nor shall any feature of a nonconforming sign, such as illumination, be increased.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign move prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. unless conforming
No nonconforming sign shall be moved for any distance on the same lot or to any other lot unless such change in location will make the sign conform in all respects to the provisions of this article.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign removal notice period15 days
If the owner or lessee fails to remove the sign structure, the zoning administrator or designee shall give the owner fifteen days' written notice to remove it.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign repair allowed
Nothing in this section shall be deemed to prevent keeping in good repair a nonconforming sign.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign repair allowed
Nothing in this section shall be deemed to prevent keeping in good repair a nonconforming sign.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign replacement requires full compliance
If such sign is so destroyed or damaged to an extent exceeding fifty percent, it shall not be reconstructed but may be replaced with a sign that is in full accordance with the provisions of this article.
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign restoration timeframe2 years
may be restored within two years after such destruction or damage
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign restoration timeframe2 years
A nonconforming sign that is destroyed or damaged by any casualty to an extent not exceeding fifty percent of its area may be restored within two years after such destruction or damage
- NonconformingNonconformingLawful when built, but not compliant with the rules now in force; usually allowed to continue but not to expand. sign verification required
Upon notice from the zoning administrator, a property owner shall submit verification that sign(s) were lawfully existing at time of erection. Failure to provide such verification shall be cause for order to remove sign(s) or bring sign(s) into compliance with the current ordinance.
- Off-site noncommercial sign area counts toward lot maximum
The area of the sign counts against the maximum sign area permitted on that lot.
- Maximum off-site noncommercial sign area16 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Each sign shall be no more than sixteen square feet in area and eight feet in height.
- Maximum off-site noncommercial sign area16 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Each sign shall be no more than sixteen square feet in area and eight feet in height.
- Maximum off-site noncommercial sign display duration30 days
Display of signs shall be limited to thirty days at a time.
- Maximum off-site noncommercial sign display duration30 days
Display of signs shall be limited to thirty days at a time.
- Maximum off-site noncommercial sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.8 ft
Each sign shall be no more than sixteen square feet in area and eight feet in height.
- Maximum off-site noncommercial sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.8 ft
Each sign shall be no more than sixteen square feet in area and eight feet in height.
- Maximum off-site noncommercial signs per lot1 signs
No more than one permitted temporary sign may be displayed per lot.
- Maximum off-site noncommercial signs per lot1 signs
No more than one permitted temporary sign may be displayed per lot.
- Maximum off-site noncommercial signs per organization3 signs
With a permit, a noncommercial use may erect up to three off-site signs on properties with the consent of the persons in charge of such properties.
- Maximum off-site noncommercial sign displays per year4 times/year
Each organization shall be limited to the display of such signs no more than four times within any calendar year.
- Maximum off-site noncommercial sign displays per year4 times/year
Each organization shall be limited to the display of such signs no more than four times within any calendar year.
- Off-site noncommercial sign permit required
With a permit, a noncommercial use may erect up to three off-site signs on properties with the consent of the persons in charge of such properties.
- Animated signs with slow message change prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.7 sec
Animated signs where the message content does not change more often than once every seven seconds.
- Signs attached to natural vegetation prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Signs attached to natural vegetation.
Billboards.
- Signs emitting sound prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Signs that emit sound.
- Signs emitting smoke, flame, scent, mist, aerosol, liquid, or gas prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Signs that emit smoke, flame, scent, mist, aerosol, liquid, or gas.
- Flashing signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Flashing signs or other signs displaying flashing, scrolling or intermittent lights or lights of changing degrees of intensity, except where such signs are expressly permitted within this article.
- Freestanding signs over 25 feet prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.25 ft
Freestanding signs more than twenty-five feet in height.
- Signs hanging from supports prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Signs hanging from supports, except against the face of a building.
- Illuminated tubing outlining building features prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.3 months/year
Signs consisting of illuminated tubing or strings of lights outlining property lines or open sales areas, rooflines, doors, windows or wall edges of any building, except for temporary decorations not to exceed a total of three months per calendar year.
- Signs in vision triangle prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Any sign located in the vision triangle formed by any two intersecting streets, as regulated by the provisions of Section 4.12.030(d).
- Moving and electronic signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. in residential districts
Moving signs and electronic message signs on residential properties in all residential districts.
- Neon signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. except in windows
Neon signs, except in windows.
- Signs not complying with regulations prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Any sign displayed without complying with all applicable regulations of this article.
- Signs not expressly permitted prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Any sign that is not expressly permitted by this article.
- Off-premises signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. unless permitted
Off-premises signs, unless specifically permitted by this article.
- Signs on public land prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. without approval
Signs erected on public land other than those approved by an authorized town official in writing, required by law without such approval, or permitted under Code of Virginia, § 24.2-310(E).
- Signs on roof or above roofline prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.5 ft
Signs on the roof surface or extending above the roofline of a building or signs extending its parapet wall where the sign is greater than five feet above the roof line.
- Signs painted directly on building prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Signs painted directly on a building, except where expressly permitted by this article.
- Pole signs under 6 feet prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.6 ft
Pole signs less than six feet in height.
- Strings of flags near public right-of-way prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.50 ft
Strings of flags visible from, and within fifty feet of, any public right-of-way.
- Signs confusing with traffic control signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Signs simulating, or which are likely to be confused with, a traffic control sign or any other sign displayed by a public authority.
- Vehicle or trailer signs prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Vehicle or trailer signs.
- Electronic signs with moving images prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.
Any electronic sign that is generated by a series of moving images, such as an LED, digital display, or other video technology, whether displayed on a building, vehicle, or mobile unit.
- Window signs over 25% of window area prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance.25 pct
Window signs whose aggregate area on a window or door exceeds twenty-five percent of the total area of the window or door.
- Projecting sign area includes sides if thick4 inches
For projecting signs with a thickness of four inches or more, the sign area also includes the area of the visible sides of the sign, calculated as a rectangle enclosing each entire side view.
- Residential temporary sign maximum display duration90 days
On residential property, one or more temporary signs with a total area of no more than twelve square feet, and which are removed within ninety days after being erected.
- Sign blank face requirement after business cessation60 days
The owner of any advertising sign, other than a permitted off-premises sign, located on commercial property where the use or business has ceased operating shall, within sixty days of the cessation of use or business operation, replace the sign face with a blank face
- Sign blank face requirement after business cessation60 days
The owner of any advertising sign, other than a permitted off-premises sign, located on commercial property where the use or business has ceased operating shall, within sixty days of the cessation of use or business operation, replace the sign face with a blank face until such time as a use or business has resumed operating on the property.
- Sign administration by Zoning Administrator
The Zoning Administrator or designee shall administer and enforce the provisions of this article. The Zoning Administrator shall have the authority to interpret the provisions of this article and to make determinations regarding the application of this article to specific properties and situations.
- Sign amendment procedure
This article may be amended from time to time in accordance with the procedures set forth in Article 10.38 of this ordinance, including public notice and hearing requirements as provided by law.
- Sign appeal timeframe30 days
Such appeal shall be filed within thirty days of the date of the decision being appealed, in accordance with the provisions of Article 10.40 of this ordinance.
- Sign area measurement method
With signs that are regular polygons or circles, the area can be calculated by the mathematical formula for that polygon or circle. With signs that are not regular polygons or circles, the sign area is calculated using all that area within a maximum of three abutting or overlapping rectangles that enclose the sign face.
- Signs must comply with Virginia Uniform Statewide Building Code
All signs shall be constructed and mounted in compliance with the Virginia Uniform Statewide Building Code.
- Signs must comply with Virginia Uniform Statewide Building Code
All signs shall be constructed and mounted in compliance with the Virginia Uniform Statewide Building Code.
- Emergency sign removal allowed without notice
The building official may cause to have removed or repaired immediately without written notice any sign which, in his opinion, has become insecure, in danger of falling, or otherwise unsafe
- Emergency sign removal allowed without notice
The building official may cause to have removed or repaired immediately without written notice any sign which, in his opinion, has become insecure, in danger of falling, or otherwise unsafe, and, as such, presents an immediate threat to the safety of the public.
- Sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. measurement method
Height means the maximum vertical distance from the base of the sign at normal grade to the top of the highest attached component of the sign. Normal grade shall be construed to be the lower of: (1) Existing grade prior to construction; or (2) The newly established grade after construction, exclusive of any filling, berming, mounding or excavating primarily for the purpose of mounting or elevating the sign.
- Audio and pyrotechnics prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. with electronic signs
Audio or pyrotechnics. Audio speakers or any form of pyrotechnics are prohibited in association with a changeable copy or electronic sign.
- Automatic dimmer required for illuminated signs
All electronic signs must be equipped with an automatic dimmer that controls the intensity of the light source.
- Sign illumination beam width limited to sign face
The beam width shall not be wider than that needed to light the sign.
- Illuminated sign intensity by day and night
The intensity of light allowed for all illuminated signs shall be eighty-five percent by day and fifty percent at night;
- Sign illumination fixtures must be full-cutoff
All lighting fixtures used to illuminate a sign shall be full-cutoff, as defined by the Illuminating Engineering Society of North America (IESNA), and shall have fully shielded or recessed luminaires with horizontal-mount flat lenses that prevent upward light scatter and protect the dark night sky.
- Sign illumination must not cause glare or light trespass
Indirect lighting shall consist of full cut-off or directionally shielded lighting fixtures that are aimed and controlled so that the directed light shall be substantially confined to the sign to minimize glare, sky glow, and light trespass.
- Electronic sign text limited to ten words10 words
Limited text. The text of the sign must be limited to ten words to allow passing motorists to read the entire copy with minimal distraction;
- Maximum sign illumination at lot line0.05 foot candles
No sign shall be permitted to have an illumination spread of more than .05 foot candle at the lot line
- Maximum sign illumination100 lumens
In no event shall the illumination of any sign resulting from any internal or external artificial light source exceed 100 lumens.
- Sign illumination must not shine into traffic or residences
No sign shall be permitted to have an illumination spread of more than .05 foot candle at the lot line, shine into on-coming traffic, affect highway safety, or shine directly into a residential dwelling unit.
- Electronic signs must be turned off at close of business
All electronic message signs must be turned off at the close of business;
- Sign illumination must be shielded
In the case of indirect lighting, the source shall be so shielded that it illuminates only the face of the sign.
- Sign provisions are minimum requirements
In the interpretation and application of this article, the provisions shall be held to be minimum requirements and shall be construed in favor of the town and not in favor of any person who seeks to violate such provisions. Where the provisions of this article impose greater restrictions than those of any other ordinance, regulation, or law, the provisions of this article shall control.
- Landscaping required around ground-mounted signs3 ft
Landscaping. All non-temporary ground-mounted or monument signs shall be installed with a minimum surround of three feet of regularly maintained floral and shrubbery landscaping in every direction.
- Signs must be maintained in good repair
All signs and components shall be maintained in good repair and in a safe, neat and clean condition.
- Signs must be maintained in good repair
All signs and components shall be maintained in good repair and in a safe, neat and clean condition.
- Maximum sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.25 ft
The maximum height for any sign shall be twenty-five feet unless otherwise specified within this article.
- Nuisance signs may be abated by town
Any sign which constitutes a nuisance may be abated by the town under the requirements of Code of Virginia, §§ 15.2-900, 15.2-906, and/or 15.2-1115.
- Nuisance signs may be abated by town
Any sign which constitutes a nuisance may be abated by the town under the requirements of Code of Virginia, §§ 15.2-900, 15.2-906, and/or 15.2-1115.
- Sign penalties
Any person who violates any provision of this article shall be subject to the penalties and enforcement procedures set forth in Article 10.36 of this ordinance, including but not limited to civil penalties, injunctive relief, and other remedies available under the Code of Virginia.
- Sign permit application requirements
An application for a sign permit shall be filed with the Zoning Administrator or designee on forms furnished by the town. The applicant shall provide sufficient information for the town to determine if the proposed sign is permitted by this article and any other applicable laws, regulations, and ordinances. An application for a temporary sign shall state the dates intended for the erection and removal of the sign.
- Sign permit approval conditions
Any application that complies with all provisions of this article, the building code, and other applicable laws, regulations, and ordinances shall be approved.
- Sign permit approval timeframe20 business days
The Zoning Administrator or designee shall promptly process the sign permit application and approve the application, reject the application, or notify the applicant of deficiencies in the application within twenty business days after receipt.
- Sign permit fee required
Fees for sign permits shall be in accordance with the schedule of fees for zoning permits as adopted by Town Council.
- Sign permit not required for A-frame signs farFloor area ratio (FAR)Total floor area divided by lot area — an FAR of 2.0 permits 20,000 sq ft of floor on a 10,000 sq ft lot. from road50 ft
A-frame signs more than fifty feet from the nearest public right of way.
- Sign permit not required for flags up to 16 sq ftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.16 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Flags up to 16 square feet in size not containing any commercial advertising; provided, that no freestanding pole shall be erected in the public right-of-way nor be within five (5) feet of a service drive, travel lane or adjoining street.
- Sign permit not required for for-sale signs on high-speed roads32 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
when the sign abuts a road with a speed limit greater than twenty-five miles per hour not more than one sign with a total area of up to thirty two square feet and a maximum height of eight feet.
- Sign permit not required for for-sale signs on low-speed roads12 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
On any property for sale or rent, not more than one sign with a total area of up to twelve square feet and a maximum height of six feet when the sign abuts a road with a speed limit of twenty-five miles per hour or less
- Sign permit not required for government signs
Signs erected by a governmental body or required by law.
- Sign permit not required for marquee message changes
The changing of messages on marquees and the repair of an existing permitted sign, except that repair of a nonconforming sign must comply with Section 10.36.020.
- Sign permit not required for up to two minor signs2 signs
Not more than two minor signs per parcel. Additional minor signs are permitted in certain zoning districts with a permit.
- Sign permit not required for official notices10 days
Official notices or advertisements posted or displayed by or under the direction of any public or court officer in the performance of his official or directed duties; provided that all such signs shall be removed within ten (10) days after their purpose has been accomplished.
- Sign permit not required for pavement markings
Pavement markings. Any sign applied directly and entirely to and flush with an asphalt, concrete, or similar paved surface.
- Sign permit not required for permanent window signs25 pct
A permanent window sign, provided that the aggregate area of all window signs on each window or door does not exceed twenty-five percent of the total area of the window or door.
- Sign permit not required for residential temporary signs12 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
On residential property, one or more temporary signs with a total area of no more than twelve square feet, and which are removed within ninety days after being erected.
- Sign permit not required for residential window signs25 pct
On residential property, window signs, provided that the total extent of window signs do not obstruct more than twenty-five percent of the total area of all windows on each building facade.
- Sign permit not required for one temporary construction sign12 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
One (1) sign, no more than twelve (12) square feet in area, located on property where a building permit is active.
- Sign permit rejection conditions
An application shall be rejected for non-compliance with the terms of this article, building code, or other applicable law, regulation, or ordinance.
- Sign permit rejection reasons must be in writing
If the application is rejected, the town shall identify the reasons for the rejection in writing.
- Sign permit required
A sign permit is required prior to the display and erection of any sign, except as provided in Section 10.34.010 of this article.
- Sign permit revocation conditions
The town may revoke a sign permit under any of the following circumstances: 1. The town determines that information in the application was materially false or misleading; 2. The sign as installed does not conform to the sign permit application; or 3. The sign violates this article, building code, or other applicable law, regulation, or ordinance.
- Sign permit void if not installed within6 months
If a sign is not installed within six months following the issuance of a sign permit (or within thirty days in the case of a temporary sign permit), the permit shall be void.
- Sign repair timeframe after notice30 days
Any sign which becomes a safety hazard or which is not kept in a reasonably good state of repair shall be put in a safe and good state of repair within thirty days of a written notice to the owner and permit holder.
- Sign repair timeframe after notice30 days
Any sign which becomes a safety hazard or which is not kept in a reasonably good state of repair shall be put in a safe and good state of repair within thirty days of a written notice to the owner and permit holder.
- Sign supports excluded from sign area
The supports, uprights or structure on which any sign is supported shall not be included in determining the sign area unless such supports, uprights or structure are designed in such a way as to form an integral background of the display
- Temporary signs shall not be illuminated
Temporary signs shall not be illuminated;
- Maximum temporary sign area (nonresidential)32 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Temporary signs shall not exceed thirty-two square feet in area and eight feet in height in nonresidential districts;
- Maximum temporary sign area (residential)12 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
Temporary signs shall not exceed twelve square feet in area and six feet in height in residential districts;
- Maximum temporary sign display duration30 days
Temporary signs shall be removed within thirty days of the date of erection
- Maximum temporary sign erections per year4 times/year
No temporary sign shall be erected more than four times per calendar year on the same property.
- Maximum temporary sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (nonresidential)8 ft
Temporary signs shall not exceed thirty-two square feet in area and eight feet in height in nonresidential districts;
- Maximum temporary sign heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. (residential)6 ft
Temporary signs shall not exceed twelve square feet in area and six feet in height in residential districts;
- Temporary sign permit maximum duration30 days
The permit for a temporary sign shall state its duration, not to exceed thirty days, unless another time is provided in the zoning ordinance.
- Temporary sign permit void if not installed within30 days
If a sign is not installed within six months following the issuance of a sign permit (or within thirty days in the case of a temporary sign permit), the permit shall be void.
- Maximum window sign coverage25 pct
A permanent window sign, provided that the aggregate area of all window signs on each window or door does not exceed twenty-five percent of the total area of the window or door.
From the ordinance
The leading edge of the electronic sign must be a minimum distance of ten feet from any street right-of-way;