Bowling Green, Virginia · General provision

10.24.060

Dimensional standards

Servicing

Applies near
Chesapeake Bay Preservation Area Map
Geographic extent
Applies to all lands identified as Chesapeake Bay Preservation Areas (CBPA) as shown on the Chesapeake Bay Preservation Area Map. Performance standards in Section 10.24.120 apply Town-wide.

Extracted standards

23 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Agricultural activities may encroach within the landward 75 feet of the one-hundred-foot wide buffer area when agricultural best management practices which address erosion control, nutrient management, and pest chemical control are being implemented

  • Agricultural activities may encroach into the landward 50 feet of the one-hundred-foot wide buffer area when at least one agricultural best management practice...is being implemented

  • achieve a forty-percent reduction in nonpoint source pollution from agricultural uses.

  • Alternating drainfield minimum area50 pct

    Each of the two alternating drainfields shall have, at a minimum, an area of not less than 50% of the area that would otherwise be required if a single primary drain field were constructed.

  • Buffer encroachment seaward limit50 ft

    The encroachment may not extend into the seaward 50 feet of the buffer area.

  • Buffer nutrient reduction40 pct

    and a forty-percent reduction of nutrients.

  • Buffer sediment reduction75 pct

    The one-hundred-foot buffer area shall be deemed to achieve a seventy-five-percent reduction of sediments

  • Resource Protection Area buffer width100 ft

    a one-hundred-foot buffer area located adjacent to and landward of the components listed above and along both sides of any water body with perennial flow.

  • Drainfield valve alternation frequency12 months

    The valve shall be used to alternate the drain fields every 12 months.

  • All development and redevelopment within a Chesapeake Bay Preservation Area resulting in 2,500 square feet or more of land disturbance shall be subject to a Plan of Development Process

  • A major water quality impact assessment shall be required for any development which exceeds 5,000 square feet of land disturbance within CBPA's and is located in an RMA.

  • Minimum two-way drive width22 ft

    Two-way drives may be a minimum of 22 feet in width.

  • A minor water quality impact assessment pertains only to development within CBPA's which causes no more than 5,000 square feet of land disturbance.

  • A nonconforming use and noncomplying structure waiver shall become null and void 12 months from the date issued if no substantial work has commenced.

  • Redevelopment nonpoint source pollution reduction10 pct

    For redevelopment sites, the nonpoint source pollution load shall be reduced by at least 10%.

  • Reserve sewage disposal site required

    A reserve sewage disposal site with a capacity at least equal to that of the primary sewage disposal site shall be provided

  • Resource Management Area width100 ft

    The Resource Management Area is composed of an area 100 feet in width surrounding Resource Protection Areas

  • Septic system pumpout frequency5 years

    All on-site sewage disposal systems not requiring a VPDES permit shall be pumped out at least once every five years

  • Tree preservation threshold2 in

    Existing trees over two inches diameter at breast height (DBH) shall be preserved outside the approved construction footprint.

  • Tree protection barrier distance from dripline5 ft

    suitable protective barriers, like safety fencing, shall be erected 5 feet outside the dripline of any tree or stand of trees to be preserved.

From the ordinance

The Chesapeake Bay Preservation Area Ordinance shall apply to all lands identified as CBPA's as designated by the Bowling Green Town Council and as shown generally on the Chesapeake Bay Preservation Area Map. All of the performance standards in Section 10.24.120 will apply Town-wide.
10.24.060