Sec. 4216, 4220, 4241, 4304, 4307, 4309, 4310, 4313, 4319, 4321
Dimensional standards
Extracted standards
23 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for multifamilyMultifamily dwellingA building of four or more dwelling units. Where zoning is most restrictive.
A type B buffer yard as specified in Article V, Division 3 shall be provided when the lot is adjacent to property zoned R-4, R-5, OTR, PR, RR1, or RR2.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for single-familySingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. attached
A type A buffer yard (see Article V) shall be required on any lot which abuts the R-4, R-5, OTR, PR, RR1, or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for two-family
A type A buffer yard shall be required on any lot which abuts the R-4, R-5, OTR, PR, RR1, or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for administrative services
A type B buffer yard shall be provided in yards adjacent to a R-4, R-5, OTR, PR, RR1 or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for clubs
A type B buffer yard shall be provided in yards adjacent to a R-4, R-5, OTR, PR, RR1 or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for cultural services
A type B buffer yard shall be provided in yards adjacent to a R-4, R-5, OTR, PR, RR1 or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for day care centerDay careSupervised care for children or adults during part of the day.
A type B buffer yard shall be provided in yards adjacent to a R-4, R-5, OTR, PR, RR1 or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for home for adults
A type B buffer yard shall be provided in yards adjacent to a R-4, R-5, OTR, PR, RR1 or RR2 zoning district.
- Buffer yardYardThe open space left between a building and its lot line — the space a setback creates. type for life care facility
A type A buffer yard shall be provided in yards adjacent to a R-4, R-5, OTR, PR, RR1 or RR2 zoning district.
- Maximum lot coverageLot coverageThe share of a lot that buildings may cover, as a percentage. for day care centerDay careSupervised care for children or adults during part of the day.45 pct
Maximum lot coverage: Forty-five (45) percent including building and all paved areas.
- Maximum lot coverageLot coverageThe share of a lot that buildings may cover, as a percentage. for home for adults45 pct
Maximum lot coverage: Forty-five (45) percent including building and all paved areas.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for multifamilyMultifamily dwellingA building of four or more dwelling units. Where zoning is most restrictive.20 ft
The minimum side setback for all new principal structures is twenty (20) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for single-familySingle-family dwellingOne dwelling unit on its own lot, usually detached from its neighbours. attached15 ft
Minimum side setback for new construction of single-family attached units: 15 feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for two-family15 ft
Minimum side setback: Fifteen (15) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for administrative services20 ft
Minimum side setback for new structures: Twenty (20) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for clubs20 ft
Minimum side setback for new structures: Twenty (20) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for cultural services20 ft
Minimum side setback: Twenty (20) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for day care centerDay careSupervised care for children or adults during part of the day.25 ft
Minimum side setback for new structures: Twenty-five (25) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for education facilities30 ft
Minimum side setback for new structures: Thirty (30) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for home for adults20 ft
Minimum side setback for new structures: Twenty (20) feet.
- Minimum side setbackSetbackThe distance a building must be held back from a lot line. for life care facility15 ft
Minimum side setback for new structures: Fifteen (15) feet.
- Retain historicHistoric districtAn area where exterior changes need design review to protect its character. character
The retention and use of existing structures that contribute to the character of the neighborhood shall be a consideration in the granting of a conditional use permit.
- Retain historicHistoric districtAn area where exterior changes need design review to protect its character. character for day careDay careSupervised care for children or adults during part of the day.
The architecture and historic character of structures in the OTR zoning district shall be retained.
From the ordinance
Additional standards in OTR: min side setback 20 ft for multifamily, 15 ft for single-family attached, etc.