Extracted standards
3 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Full cutoff luminaries required
All exterior lights will be full cutoff luminaries.
- Maximum maintained horizontal illuminance at grade
The maintained horizontal illuminance at grade at adjoining streets shall not exceed 0.5 foot candles, and the maintained horizontal illuminance at grade at adjoining residential properties shall not exceed 0.1 foot candles.
- Maximum pole heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. by districtZoning districtA mapped area with one set of rules, identified by a code like R-1 or B-2.
Poles supporting lights shall be no taller than twenty (20) feet in a residential district, twenty-five (25) feet in a commercial or office district or a commercial part of a planned development residential district, twenty-five (25) feet in a MXD Development district (regardless of use), and thirty (30) feet in any industrial district.
From the ordinance
The maintained horizontal illuminance at grade at adjoining streets shall not exceed 0.5 foot candles, and the maintained horizontal illuminance at grade at adjoining residential properties shall not exceed 0.1 foot candles.