Extracted standards
4 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum architectural screening heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.4 ft
Architectural screening shall be at least four (4) feet in height, shall be supplemented with plantings.
- Screening required for storage, refuse, mechanical equipment
Screening shall be provided for all articles or materials being stored, refuse storage and loading areas, rooftop and ground level mechanical equipment, and trash dumpsters.
- Maximum screening tree spacing12 ft
at the time of planting, the spacing of trees shall not exceed twelve (12) feet on center, and the planting pattern shall be staggered.
- Vegetative screening heights
Small evergreen trees shall be at least four (4) feet in height at planting and allowed to grow to at least six (6) feet in height. Large evergreen trees shall be at least six (6) feet in height at planting and allowed to grow to at least ten (10) feet in height. Deciduous trees shall be at least one and one-half (1½) inches caliper or ten (10) feet to twelve (12) feet in height.
From the ordinance
Screening shall be provided, in addition to the requirements listed above, for: (1) All articles or materials being stored... Architectural screening shall be at least four (4) feet in height... Small evergreen trees shall be at least four (4) feet in height at planting... spacing of trees shall not exceed twelve (12) feet on center.