Blacksburg, Virginia · General provision

Sec. 5120

Extracted standards

8 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Floodplain

Other

  • Where easements do not follow the established lot lines, the nearest edge of any easement shall be a minimum of five (5) feet from any building.

  • Minimum easement width15 ft

    Minimum easement width shall be fifteen (15) feet unless specifically reduced by the Administrator, based on need or the physical characteristics of the site.

  • Sidewalk requirement along developed streets

    Sidewalks meeting the design standards of the Subdivision Ordinance shall be provided on public or private land along all parts of a site abutting a developed public street, where such sidewalks do not exist as of the date of the application for site plan approval.

  • Sidewalk waiver conditions

    The Zoning Administrator may lessen or eliminate the requirements of this subsection based on conditions such as no existing sidewalk network, no transit stops within a quarter-mile, or natural constraints.

  • Storm drainage design storm10 year

    All storm drainage improvements shall be designed to carry the ten-year storm.

From the ordinance

Sidewalks meeting the design standards of the Subdivision Ordinance shall be provided on public or private land along all parts of a site abutting a developed public street, where such sidewalks do not exist as of the date of the application for site plan approval.
Sec. 5120