Dimensional standards
Extracted standards
3 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Fencing & walls
- Masonry wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in front/street sideSetbackThe distance a building must be held back from a lot line. yardYardThe open space left between a building and its lot line — the space a setback creates.3 ft
three feet high within the required front or street side yard area
- Masonry wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. adjacent to residential6 ft
six feet in height
- Masonry wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. within 10 ft of street line when no yardYardThe open space left between a building and its lot line — the space a setback creates. required3 ft
three feet high within ten feet of the street line
From the ordinance
When adjoining or across an alley from any residentially zoned or residentially used lot, a masonry wall six feet in height shall be erected and maintained so as to physically separate the parking, loading or sales area from the residential property; provided that such wall shall be three feet high within the required front or street side yard area, or, where no front or street side yard area is required, such wall shall be three feet high within ten feet of the street line.