Riverside, California · General provision

19.580.060, 19.580.070, 19.580.080

Dimensional standards

lot requirementsSTREETMIN LOT AREA3,499 sq ft
Plan view of the district’s stated lot requirements. Solid line: the property line. Dashed: the setback lines the ordinance imposes; a building must stay inside the tinted envelope. Drawn from the figures extracted below — illustrative, not a survey.

Extracted standards

44 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Fencing & walls

Other

  • Compost incorporation rate4 cuyd/1000sqft

    Incorporate compost at a rate of at least four cubic yards per 1,000 square feet to a depth of six inches.

  • Automatic irrigation controller requirement

    Automatic irrigation controllers are required and must use evapotranspiration or soil moisture sensor data.

  • For nonresidential projects with landscape of 1,000 square feet or more, a dedicated landscape meter(s) shall be installed.

  • Manual shut-off valve requirement

    Manual shut-off valves shall be installed as close as possible to the point of connection of the water supply.

  • Minimum mulch depth3 in

    A minimum three inch layer of mulch shall be applied on all exposed soil surfaces of planting areas.

  • Irrigation method for narrow areas10 ft

    Areas less than ten feet in width in any direction shall be irrigated with subsurface irrigation or other means that produce no runoff or overspray.

  • Required parking, loading areas and circulation areas shall be paved with not less than three inches of asphalt concrete.

  • Driveways and turning and maneuvering areas in parking structure shall be paved with not less than two and one-half inches of asphaltic concrete.

  • Pedestrian path requirement

    All multi-family and nonresidential developments shall be designed with a minimum of one designated pedestrian path from each abutting street to the primary entrance(s).

  • Average plant factor (nonresidential)0.3

    For nonresidential areas, install climate adapted plants that require occasional, little or no summer water (average WUCOLS plant factor 0.3) for 100 percent of the plant area.

  • Average plant factor (residential)0.3

    For residential areas, install climate adapted plants that require occasional, little or no summer water (average WUCOLS plant factor 0.3) for 75 percent of the plant area.

  • Pressure regulator requirement

    Pressure regulators shall be installed on the irrigation system.

  • Minimum sprinkler distribution uniformity0.65

    All sprinkler heads installed in the landscape must document a distribution uniformity low quarter of 0.65 or higher.

  • Maximum turf area (nonresidential)0 pct

    there shall be no turf in nonresidential areas.

  • Maximum turf area (residential)25 pct

    Turf shall not exceed 25 percent of the landscape area in residential areas.

  • Minimum parkway width for turf10 ft

    Turf is prohibited in parkways less than ten feet wide.

  • Maximum slope for turf0.25 ratio

    Turf shall not be planted on sloped areas which exceed a slope of one foot vertical elevation change for every four feet of horizontal length.

Parking

From the ordinance

ADU/JADU: No parking required. Multiple family: 75% covered. Parking structures: 15 ft landscaped setback (10 ft in downtown area).
19.580.060, 19.580.070, 19.580.080

Parking requirements

{
  "ADU/JADU": "No parking required",
  "Emergency Shelter": "Sufficient parking for all staff on largest shift",
  "Single-family dwelling": "See Table 19.580.060",
  "Multiple-family dwelling": "See Table 19.580.060; 75% covered"
}