Chapter 19.556, Sections 19.556.010-19.556.080
Extracted standards
6 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Outdoor lighting shall be downward facing
Outdoor lighting shall be downward facing, except as may be specifically allowed herein.
- Maximum correlated color temperature3,000 K
The correlated color temperature of all outdoor lighting shall be 3,000 Kelvin or less, with tolerance within the ANSI standard C78.377 of LED sources.
- Maximum average illumination of façade5 fc
Average illumination of a façade or edifice shall not exceed five footcandles (50 lux).
- Maximum luminaire intensity500,000 candelas
Luminaires exceeding 500,000 peak candelas or 50,000 lumens
- Maximum mounting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for buildings with exterior entrance doors12 ft
the maximum mounting height for buildings with exterior entrance doors shall be 12 feet above adjacent floor unless recessed into an adjacent ceiling, soffit or overhang.
- ProhibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. dynamic lighting
Dynamic lighting, such as moving lights, color changing lighting, or digital LED panels that flash, chase, change color, or changes intensity for any purpose other than serving as a traffic signal, safety light, or aviation or marine marker.
From the ordinance
All outdoor lighting shall be designed and implemented to mitigate light trespass onto adjacent properties and comply with the following: correlated color temperature 3,000 Kelvin or less; comply with Title 24; etc.