Rancho Palos Verdes, California · General provision

17.06.020 (referenced in text)

Extracted standards

3 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Minimum floor/ceiling IIC rating55 IIC

    and a minimum rating of 55 IIC (impact insulation class)

  • Minimum floor/ceiling STC rating50 STC

    All common floor/ceiling assemblies which separate dwelling units from each other or from public or quasi-public spaces (interior corridors, laundry rooms, recreation rooms and garages) shall be constructed with a minimum rating of 50 STC (sound transmission class) and a minimum rating of 55 IIC (impact insulation class).

  • Minimum wall STC rating55 STC

    All common wall assemblies which separate dwelling units from each other or from public or quasi-public spaces (interior corridors, laundry rooms, recreation rooms and garages) shall be constructed with a minimum rating of 55 STC (sound transmission class).

From the ordinance

All common wall assemblies which separate dwelling units from each other or from public or quasi-public spaces (interior corridors, laundry rooms, recreation rooms and garages) shall be constructed with a minimum rating of 55 STC (sound transmission class).
17.06.020 (referenced in text)