Rancho Palos Verdes, California · General provision

17.06

Extracted standards

8 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • All common wall assemblies which separate all other attached dwelling units or a dwelling unit and a public or quasi-public space shall be of a staggered-stud construction.

  • All common wall assemblies which separate attached single-family units shall be of a cavity-type construction.

  • Minimum IIC rating for common floor/ceiling assemblies55 IIC

    All common floor/ceiling assemblies shall be constructed with a minimum rating of 55 IIC.

  • Minimum STC rating for common floor/ceiling assemblies50 STC

    All common floor/ceiling assemblies which separate dwelling units from each other or from public or quasi-public spaces shall be constructed with a minimum rating of 50 STC.

  • Minimum STC rating for common walls55 STC

    All common wall assemblies which separate dwelling units from each other or from public or quasi-public spaces shall be constructed with a minimum rating of 55 STC.

  • Plumbing fixture placement relative to common walls

    No plumbing fixture or other such permanent device which generates noise or vibration shall be attached to a common wall adjacent to a living room, family room, dining room, den or bedroom of an adjoining unit.

  • Utility easements over private streets

    If private streets are involved, a provision shall be made for public utility easements over the entire private street network.

  • Water supply line isolation in common walls

    All water supply lines within common walls and/or floors/ceilings shall be isolated from wood or metal framing with pipe isolators specifically manufactured for that purpose.

From the ordinance

This chapter provides supplemental development standards which shall apply to all residential structures which are constructed with common walls and/or floor/ceiling assemblies.
17.06