County (unincorporated) · Virginia

Prince William County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
16
Districts
601
Extracted rules
1,997
Standards
10
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

16 districts, grouped by category.

General provisions

581 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Sec. 32-250.931 standards

Underground storage tanks shall be located in accordance with the following setback requirements: ...

Sec. 32-250.931 standards

All underground storage tanks shall be set back from property lines either in accordance with the requirements for setbacks for accessory structures for the zoning district in which they are located, or in accordance with health department standards, whichever is stricter.

Sec. 32-280.101 standards

Planned development districts shall be established by amendment to the Zoning Map, in accordance with the provisions of Article VII of this chapter; ...

Sec. 32-280.111 standards

The master zoning plan shall designate land bays for the various land uses proposed in the planned development district.

Sec. 32-280.122 standards

Except in town centers, all buildings and other principal structures shall be set back at least 30 feet from all street rights-of-way. No rear or side yards are required except that every building shall have access for emergency response purposes.

Sec. 32-280.121 standards

Nonresidential areas in planned development districts shall comply with the following general development standards: ...

Sec. 32-280.123 standards

Outdoor storage shall be prohibited within planned development districts, unless specifically approved by proffer or Special Use Permit condition for M-2, Light Industrial, uses. Except in town centers, all buildings and other principal structures shall be set back at least 30 feet from all street rights-of-way. No rear or side yards are required except that every building shall have access for emergency response purposes.

Sec. 32-280.132 standards

The Planning Director may approve a use that is comparable to a use listed in the master zoning plan, upon a finding that: ...

Sec. 32-280.301 standards

The town center provisions set forth in this division are intended to encourage the development of mixed-use town centers that provide a focal point for the community and a variety of uses, including retail, office, residential, and public uses.

Sec. 32-280.30 and 32-280.313 standards

Town centers shall be established by Special Use Permit in any PMD or PMR zoning district. A town center shall be no less than 40 contiguous acres and no more than 250 contiguous acres in size.

Sec. 32-280.314 standards

A town center shall be no less than 40 contiguous acres and no more than 250 contiguous acres in size.

Sec. 32-280.414 standards

The maximum height for any building or structure shall be 100 feet. The minimum height shall be 30 feet. ... At least 50 percent of the aggregate net floor area in the mixed residential and commercial land bay(s) shall contain residential dwellings that shall only be permitted on the second or higher floors.

Sec. 32-280.415 standards

The maximum height for any building or structure shall be 100 feet. The minimum height shall be 30 feet. At least 50 percent of the aggregate net floor area in the mixed residential and commercial land bay(s) shall contain residential dwellings...

Sec. 32-280.514 standards

The principal uses allowed in this land bay shall be multifamily buildings and mid- to high-rise buildings... Minimum height of all multifamily or mid- to high-rise buildings shall be 35 feet. ... For multifamily or mid- to high-rise buildings and any attachments thereto, there shall be a minimum separation of 20 feet.

Sec. 32-280.516 standards

The principal uses allowed in this land bay shall be multifamily buildings and mid- to high-rise buildings... Minimum height of all multifamily or mid- to high-rise buildings shall be 35 feet.

Sec. 32-280.617 standards

Townhouse uses may have zero lot line yards and setbacks except the rear setback shall be at least 30 feet and for corner lots, the side setback shall be ten feet. ... Maximum townhouse building height shall be 50 feet. ... A maximum lot coverage of 75 percent shall be allowed.

Sec. 32-280.6112 standards

Townhouse uses may have zero lot line yards and setbacks except the rear setback shall be at least 30 feet and for corner lots, the side setback shall be ten feet. ... Maximum townhouse building height shall be 50 feet.

Sec. 32-280.714 standards

The principal use allowed in this land bay shall be single-family detached dwelling units... The front setback for single-family detached dwellings shall be ten feet measured to the front porch, excluding steps. The rear setback for the principal dwelling shall be at least 30 feet and side setbacks can be zero feet with maintenance easements, except for corner lots the side setback, including any porches, shall be ten feet.

Sec. 32-280.716 standards

The principal use allowed in this land bay shall be single-family detached dwelling units... The front setback for single-family detached dwellings shall be ten feet measured to the front porch, excluding steps. The rear setback for the principal dwelling shall be at least 30 feet and side setbacks can be zero feet with maintenance easements, except for corner lots the side setback, including any porches, shall be ten feet.

Sec. 32-290.01 - 32-290.067 standards

This Affordable Dwelling Unit Ordinance is adopted pursuant to Virginia Code § 15.2-2305.1, to address housing needs... (Sec. 32-290.01)

Source documents