M-1
Dimensional standards
Uses
Permitted by right40
- assembly of electrical appliances
- assembly of electronic instruments and devices
- assembly of radios and phonographs
- manufacture of small parts such as coils, condensers, transformers and crystal holders
- laboratories, pharmaceutical and medical
- manufacture and sale of pottery and ceramic products
- ceramic studios
- manufacture of musical instruments
- manufacture of toys
- manufacture of novelties
- manufacture of rubber and metal stamps
- plumbing supplies storage
- coalyards
- woodyards
- cabinet shops
- furniture shops
- upholstery shops
- boat manufacturer
- monumental stoneworks
- wholesale businesses
- warehouses
- public utilities and facilities
- truck terminals
- sawmills
- contractors' equipment storage or yards
- contractors' equipment rental, sales or service
- beverage distributors or bottling plants
- sheetmetal, blacksmith, welding or machine shops
- manufacture, compounding, processing, packaging or treatment of articles or merchandise from previously prepared materials
- state department of transportation maintenance facilities
- lumber, building supplies, plumbing and electrical supplies
- print plants
- commercial transmitter towers
- pulp and paper manufacture
- steel fabricating plants
- public safety facilities serving the neighborhood, such as fire and rescue stations
- public water and sewer systems
- recycling facility, up to 3,000 square feet including outside storage areas
- storage facilities
- solar generation facilities, small
Conditional / special use8
- industrial activity or manufacturing concern involving the manufacturing or storage of toxic chemicals or materials
- mineral processing operations such as cement, lime and gypsum manufacture
- masonry block and brick manufacture
- asphalt plants
- meat, poultry and fish processing
- bulk petroleum storage
- transfer stations
- recycling facility, over 3,000 square feet including outside storage areas
Extracted standards
10 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Height
- Maximum parapet wall heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.4 ft
Parapet walls are permitted up to four feet above the limited height of the building on which the walls rest.
Other
- Front setbackSetbackThe distance a building must be held back from a lot line. from street centerline65 ft
or 65 feet or more from the centerline of any street or road right-of-way less than 50 feet in width
- Front setbackSetbackThe distance a building must be held back from a lot line. from street right-of-way40 ft
no building shall be located or structurally altered nearer to the street or road on which it faces than 40 feet or more from any street or road right-of-way, which is over 50 feet or greater in width
- Landscaping clearance from driveway30 ft
to within 30 feet of the corner where a driveway intersects with a street
- Landscaping clearance from intersection50 ft
to within 50 feet from the corner of any two intersecting streets
- Landscaping required for uncovered area
Any area not covered by buildings, pavement or designed for parking shall be landscaped and maintained.
- Landscaping required in front setbackSetbackThe distance a building must be held back from a lot line.
Landscaping is required within an established or required front setback area. The plans and execution must take into consideration traffic hazards. Landscaping may be permitted up to a height of three feet and to within 50 feet from the corner of any two intersecting streets or to within 30 feet of the corner where a driveway intersects with a street.
- Maximum landscaping heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.3 ft
Landscaping may be permitted up to a height of three feet
- Minimum distance between structures10 ft
Where more than one main structure or use is permitted on the same lot, there shall be a minimum of ten feet separation between building or use and shall meet the required minimum setback.
- Screening required near residential districts6 ft
Where acceptable uses are within 300 feet of an R-1 or R-2 residential district or within 300 feet of an existing residence in any other district, they shall be conducted wholly within a completely enclosed building or within an area appropriately screened on the side facing the district, by a solid masonry wall, a uniformly painted solid wood fence or an evergreen hedge six feet in height.
From the ordinance
The M-1 industrial district is composed of industrial uses which must be served by public water and sewerage or a suitable, approved, private water and sewer system.